@ -18,6 +18,11 @@ enum class ErrorCode : uint_fast16_t {
|
||||||
RUNNING = 0x0000, ///< the operation is still running - keep this value as ZERO as it is used for initialization of error codes as well
|
RUNNING = 0x0000, ///< the operation is still running - keep this value as ZERO as it is used for initialization of error codes as well
|
||||||
OK = 0x0001, ///< the operation finished OK
|
OK = 0x0001, ///< the operation finished OK
|
||||||
|
|
||||||
|
// TMC bit masks
|
||||||
|
TMC_PULLEY_BIT = 0x0040, ///< +64 TMC Pulley bit
|
||||||
|
TMC_SELECTOR_BIT = 0x0080, ///< +128 TMC Pulley bit
|
||||||
|
TMC_IDLER_BIT = 0x0100, ///< +256 TMC Pulley bit
|
||||||
|
|
||||||
/// Unload Filament related error codes
|
/// Unload Filament related error codes
|
||||||
FINDA_DIDNT_SWITCH_ON = 0x8001, ///< E32769 FINDA didn't switch on while loading filament - either there is something blocking the metal ball or a cable is broken/disconnected
|
FINDA_DIDNT_SWITCH_ON = 0x8001, ///< E32769 FINDA didn't switch on while loading filament - either there is something blocking the metal ball or a cable is broken/disconnected
|
||||||
FINDA_DIDNT_SWITCH_OFF = 0x8002, ///< E32770 FINDA didn't switch off while unloading filament
|
FINDA_DIDNT_SWITCH_OFF = 0x8002, ///< E32770 FINDA didn't switch off while unloading filament
|
||||||
|
|
@ -29,6 +34,11 @@ enum class ErrorCode : uint_fast16_t {
|
||||||
|
|
||||||
INVALID_TOOL = 0x8006, ///< E32774 tool/slot index out of range (typically issuing T5 into an MMU with just 5 slots - valid range 0-4)
|
INVALID_TOOL = 0x8006, ///< E32774 tool/slot index out of range (typically issuing T5 into an MMU with just 5 slots - valid range 0-4)
|
||||||
|
|
||||||
|
HOMING_FAILED = 0x8007, ///< generic homing failed error - always reported with the corresponding axis bit set (Idler or Selector) as follows:
|
||||||
|
HOMING_SELECTOR_FAILED = HOMING_FAILED | TMC_SELECTOR_BIT, ///< E32903 the Selector was unable to home properly - that means something is blocking its movement
|
||||||
|
HOMING_IDLER_FAILED = HOMING_FAILED | TMC_IDLER_BIT, ///< E33031 the Idler was unable to home properly - that means something is blocking its movement
|
||||||
|
STALLED_PULLEY = HOMING_FAILED | TMC_PULLEY_BIT, ///< E32839 for the Pulley "homing" means just stallguard detected during Pulley's operation (Pulley doesn't home)
|
||||||
|
|
||||||
QUEUE_FULL = 0x802b, ///< E32811 internal logic error - attempt to move with a full queue
|
QUEUE_FULL = 0x802b, ///< E32811 internal logic error - attempt to move with a full queue
|
||||||
|
|
||||||
VERSION_MISMATCH = 0x802c, ///< E32812 internal error of the printer - incompatible version of the MMU FW
|
VERSION_MISMATCH = 0x802c, ///< E32812 internal error of the printer - incompatible version of the MMU FW
|
||||||
|
|
@ -36,12 +46,6 @@ enum class ErrorCode : uint_fast16_t {
|
||||||
MMU_NOT_RESPONDING = 0x802e, ///< E32814 internal error of the printer - communication with the MMU is not working
|
MMU_NOT_RESPONDING = 0x802e, ///< E32814 internal error of the printer - communication with the MMU is not working
|
||||||
INTERNAL = 0x802f, ///< E32815 internal runtime error (software)
|
INTERNAL = 0x802f, ///< E32815 internal runtime error (software)
|
||||||
|
|
||||||
// TMC bit masks
|
|
||||||
|
|
||||||
TMC_PULLEY_BIT = 0x0040, ///< +64 TMC Pulley bit
|
|
||||||
TMC_SELECTOR_BIT = 0x0080, ///< +128 TMC Pulley bit
|
|
||||||
TMC_IDLER_BIT = 0x0100, ///< +256 TMC Pulley bit
|
|
||||||
|
|
||||||
/// TMC driver init error - TMC dead or bad communication
|
/// TMC driver init error - TMC dead or bad communication
|
||||||
/// - E33344 Pulley TMC driver
|
/// - E33344 Pulley TMC driver
|
||||||
/// - E33404 Selector TMC driver
|
/// - E33404 Selector TMC driver
|
||||||
|
|
|
||||||