Add new error codes
parent
db2125e67a
commit
2b5a129c7d
|
|
@ -90,7 +90,7 @@ bool EjectFilament::StepInner() {
|
|||
default:
|
||||
break;
|
||||
}
|
||||
return false;
|
||||
break;
|
||||
}
|
||||
case ProgressCode::OK:
|
||||
return true;
|
||||
|
|
|
|||
|
|
@ -49,10 +49,15 @@ enum class ErrorCode : uint_fast16_t {
|
|||
FINDA_FLICKERS = 0x800a, ///< FINDA flickers - seems to be badly calibrated and happens to be pressed at spots where it used to be not pressed before.
|
||||
///< The user is obliged to inspect FINDA and tune its switching
|
||||
|
||||
FILAMENT_EJECTED = 0x800b, ///< Filament was ejected, waiting for user input - technically, this is not an error
|
||||
MOVE_FAILED = 0x800b, ///< generic move failed error - always reported with the corresponding axis bit set (Idler or Selector) as follows:
|
||||
MOVE_SELECTOR_FAILED = MOVE_FAILED | TMC_SELECTOR_BIT, ///< E32905 the Selector was unable to move to desired position properly - that means something is blocking its movement, e.g. a piece of filament got out of pulley body
|
||||
MOVE_IDLER_FAILED = MOVE_FAILED | TMC_IDLER_BIT, ///< E33033 the Idler was unable to move - unused at the time of creation, but added for completeness
|
||||
MOVE_PULLEY_FAILED = MOVE_FAILED | TMC_PULLEY_BIT, ///< E32841 the Pulley was unable to move - unused at the time of creation, but added for completeness
|
||||
|
||||
FILAMENT_EJECTED = 0x800c, ///< Filament was ejected, waiting for user input - technically, this is not an error
|
||||
|
||||
LOAD_TO_EXTRUDER_FAILED = 0x802a, ///< E32811 internal error of the printer - try-load-unload sequence detected missing filament -> failed load into the nozzle
|
||||
QUEUE_FULL = 0x802b, ///< E32811 internal logic error - attempt to move with a full queue
|
||||
|
||||
VERSION_MISMATCH = 0x802c, ///< E32812 internal error of the printer - incompatible version of the MMU FW
|
||||
PROTOCOL_ERROR = 0x802d, ///< E32813 internal error of the printer - communication with the MMU got garbled - protocol decoder couldn't decode the incoming messages
|
||||
MMU_NOT_RESPONDING = 0x802e, ///< E32814 internal error of the printer - communication with the MMU is not working
|
||||
|
|
|
|||