Fix issue with MMU2S not loading filament correctly
Adapted angle to fix load issue on MMU2S (lot of load failures). Since firmware rebuild with this new angle, I do not have any load issue - lot of print made using PETG with this adapted version). To test on MMU3S as I do not have such device at home.pull/347/head
parent
75570a82ff
commit
4859fc0a81
|
|
@ -201,7 +201,8 @@ static constexpr IdlerLimits idlerLimits = {
|
||||||
};
|
};
|
||||||
|
|
||||||
static constexpr U_deg IdlerSlotDistance = 40.0_deg; /// Idler distance between two slots
|
static constexpr U_deg IdlerSlotDistance = 40.0_deg; /// Idler distance between two slots
|
||||||
static constexpr U_deg IdlerOffsetFromHome = 18.0_deg; /// Idler offset from home to slots
|
// RCU Test Patch MMU2S : adapted home offset from 18 to 25 deg
|
||||||
|
static constexpr U_deg IdlerOffsetFromHome = 25.0_deg; /// Idler offset from home to slots
|
||||||
|
|
||||||
/// Absolute positions for Idler's slots: 0-4 are the real ones, the 5th index is the idle position
|
/// Absolute positions for Idler's slots: 0-4 are the real ones, the 5th index is the idle position
|
||||||
/// Home ccw with 5th idler bearing facing selector
|
/// Home ccw with 5th idler bearing facing selector
|
||||||
|
|
|
||||||