This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Introduce axisUnitToTruncatedUnit to convert from an AxisUnit (now
conveniently returned from Motion::CurPosition) to a physical unit *but*
directly into a truncated integer type, avoiding conversions to long
double types at runtime.
The related function truncatedUnit perform the same truncation of a
constant unit, so that the result of axisUnitToTruncatedUnit and
truncatedUnit(unit) result in the same type for clarity.
Both functions accept a pre-multiplier, which is applied at compile
time for constant values when optimizations are enabled.
This solves a number of issues - if FINDA or FSensor failed,
the unload was never "complete" - filament was stuck in the selector
blocking it from normal operation.
Now, after all errors have been resolved, filament is explicitly FED
into FINDA and then RETRACTED to Pulley.
Slower loading speed is necessary for precise detection
of filament sensor trigger and starting rotation of the E-motor.
Experimentally it turned out speeds above 80mm/s tend to cause timing issues
(sometimes one can hear a crack as MMU' or the printer's drive gears
slip while pushing the filament).
Such a timing issue then causes blobs in purge towers.
On the other hand - 80mm/s for the fast part of filament load
seems not only absolutely reliable, but also very quiet.
120mm/s for unload is much louder (we may slow it down later)
In AVR __builtin_abs() breaks for non-base types.
Provide a generic function and use an overload when it is safe to use
instead.
This fixes the underlying step count calculation in PlanMove, thus
removing the need for the PlanLongMove work-around.