Commit Graph

10 Commits (87a1862161a0016bb422555d7efae86287783446)

Author SHA1 Message Date
Guðni Már Gilbert 87a1862161 optimisation: calculate steps per unit reciprocal at compile time
Using the reciprocal allows us to use multiplication instead of division at runtime.

This commit removes 7 divison operations at run time.

Change in memory:
Flash: -210 bytes
SRAM: 0 bytes
2024-12-24 13:47:23 +00:00
D.R.racer b16ac63c5d Compute vSense dynamically from iRun/iHold 2022-12-29 09:01:27 +01:00
Alex Voinea a87b981a3d Homing initial 2021-10-21 07:55:41 +02:00
D.R.racer 0fbcb9dac2 Tag all source files with @file for doxygen 2021-10-18 17:59:46 +02:00
Yuri D'Elia 288e74283d Introduce config::MRes and fix (real) axis units
The parameter config::AxisConfig::uSteps was supposed to be
microstepping resolution, but it's instead being used as the driver's
MRES directly.

To avoid a runtime conversion, rename the field to mRes and define a new
enum listing all the possible (and valid) microstepping resolutions.

This simplifies the code and makes clear the stepsPerUnit scale.

Assign correct stepsPerUnit to all axes as a result, including working
limits.
2021-08-25 09:16:56 +02:00
Alex Voinea e9046eed42 tmc2130: More init 2021-07-29 10:01:33 +02:00
Yuri D'Elia 187858d228 Move config/unit.h to unit.h and it's own namespace 2021-07-25 22:14:56 +02:00
Yuri D'Elia 888cdf7cd5 Introduce compile-time axis unit type checks and conversions
Introduces:

- config::Unit: base class for physical quantities
- motion::AxisUnit: type-checked steps type

"config/unit.h" defines basic physical quantities, which are not
normally used elsewhere besides config.h.

"modules/axisunit.h" extends the modules::motion namespace with
Axis-aware units, with one type per axis per unit.

P_pos_t defines step positions for the pulley, I_pos_t for the idler,
etc. These are defined through the literar operators which are
similarly named and automatically convert a physical quantity to an
AxisUnit at compile time:

P_pos_t pulley_pos = 10.0_P_mm;

Besides type-checking, AxisUnit are otherwise identical to raw step
counts and are intended to be used along with the updated Motion API.

PlanMove/PlanMoveTo has been extended to support moves using these units
or physical quantities. Again, conversion is performed at compile time.
2021-07-25 16:39:54 +02:00
Yuri D'Elia d87db1ff76 Revised WIP for the Motion API
- Remove the combined PlanMove(a,b,c,rate) call. If we allow the units
  of the various motors to be changed at compile time, the unit of
  rate can vary between axes.
- Build PlanMove on top of the absolute PlanMoveTo.
- Add required stubs for TMC2130.
- Allow each axis mode to be set independently, since we have this
  feature for free anyway.
- Rework internals to use PulseGen data types and structs.
2021-07-07 16:59:39 +02:00
Yuri D'Elia de88ed4c6b Add initial Axis configuration static structs 2021-07-07 16:59:04 +02:00