Needs to be tweaked further to make it a production code.
But my primary concern now is the fact that it doesn't seem to help too much while homing over the too-tightened Idler cover.
This is to solve a potential problem while feeding to printer's drive gears - while disengaging the Idler, the Pulley was still rotating to avoid grinding the filament (printer is pulling it).
Other filaments could have moved a bit when the Idler's bearings ran over them while the Pulley was still rotating slowly -> the filament could have been moved into the Selector's path causing trouble (especially when not used in the print).
Therefore, the Idler disengages partially now - moves into an intermediate position between the slots.
Then, the Pulley is completely stopped and after that the Idler does a full disengage like before.
The principle has been implemented, but the TMC is not providing
the right data for some reason - homing doesn't work at all right now.
Also, after solving the physical homing, unit tests must be updated.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Both movable components now perform homing sequences transparently
whenever the logic layer invalidates the homingValid flag.
That reflects the fact, that the user may have moved the Idler or Selector
while trying to resolve a HW issue with un/loading filament.
Basic rules:
- Idler gets rehomed immediately and then moves into the target slot position
- Selector rehomes once it is possible - i.e. when filament load state
is AtPulley - then it immediately and spontanneously executes the homing
sequence and then returns to the desired state
Motivation:
- resolve startup issues (EEPROM says we have filament, but FINDA is not triggered)
- resolve accidental moves of Idler and/or Selector while
digging out stuck filament from the unit
- fix homing procedure for Idler and Selector
(homing now ends with a move to the Parking position)
- fix unit tests' startup conditions with regard to necessary
homing of Idler and Selector
TODO: still test_cut_filament fails for minor reasons