Adds unit migration functionality to options flow
Implements a user interface to migrate units for rain sensors including migration of historic data via statistics. This provides the user with the ability to correct rain units, if they have been set incorrectly. Includes UI to select sensor and units, as well as trigger migration.pull/65/head
parent
af87fd0719
commit
99d25bfd56
|
|
@ -1,13 +1,15 @@
|
|||
"""Config flow for Sencor SWS 12500 Weather Station integration."""
|
||||
|
||||
import logging
|
||||
from typing import Any
|
||||
|
||||
import voluptuous as vol
|
||||
|
||||
from homeassistant.config_entries import ConfigFlow, OptionsFlow
|
||||
from homeassistant.const import UnitOfPrecipitationDepth, UnitOfVolumetricFlux
|
||||
from homeassistant.core import callback
|
||||
from homeassistant.exceptions import HomeAssistantError
|
||||
from .utils import long_term_units_in_statistics_meta, migrate_data
|
||||
import homeassistant.helpers.entity_registry as er
|
||||
|
||||
from .const import (
|
||||
API_ID,
|
||||
|
|
@ -15,13 +17,18 @@ from .const import (
|
|||
DEV_DBG,
|
||||
DOMAIN,
|
||||
INVALID_CREDENTIALS,
|
||||
SENSORS_TO_LOAD,
|
||||
MIG_FROM,
|
||||
MIG_TO,
|
||||
SENSOR_TO_MIGRATE,
|
||||
SENSORS_TO_LOAD,
|
||||
WINDY_API_KEY,
|
||||
WINDY_ENABLED,
|
||||
WINDY_LOGGER_ENABLED,
|
||||
WSLINK,
|
||||
)
|
||||
from .utils import long_term_units_in_statistics_meta, migrate_data
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
class CannotConnect(HomeAssistantError):
|
||||
|
|
@ -41,16 +48,23 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
|
||||
self.windy_data: dict[str, Any] = {}
|
||||
self.windy_data_schema = {}
|
||||
self.user_data: dict[str, str] = {}
|
||||
self.user_data: dict[str, Any] = {}
|
||||
self.user_data_schema = {}
|
||||
self.sensors: dict[str, Any] = {}
|
||||
self.migrate_schema = {}
|
||||
self.migrate_sensor_select = {}
|
||||
self.migrate_unit_selection = {}
|
||||
self.count = 0
|
||||
self.selected_sensor = ""
|
||||
|
||||
self.unit_values = [unit.value for unit in UnitOfVolumetricFlux]
|
||||
self.unit_values.extend([unit.value for unit in UnitOfPrecipitationDepth])
|
||||
|
||||
@property
|
||||
def config_entry(self):
|
||||
return self.hass.config_entries.async_get_entry(self.handler)
|
||||
|
||||
def _get_entry_data(self):
|
||||
async def _get_entry_data(self):
|
||||
"""Get entry data."""
|
||||
|
||||
self.user_data: dict[str, Any] = {
|
||||
|
|
@ -61,10 +75,10 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
}
|
||||
|
||||
self.user_data_schema = {
|
||||
vol.Required(API_ID, default=self.user_data[API_ID] or ""): str,
|
||||
vol.Required(API_KEY, default=self.user_data[API_KEY] or ""): str,
|
||||
vol.Optional(WSLINK, default=self.user_data[WSLINK]): bool or False,
|
||||
vol.Optional(DEV_DBG, default=self.user_data[DEV_DBG]): bool or False,
|
||||
vol.Required(API_ID, default=self.user_data.get(API_ID, "")): str,
|
||||
vol.Required(API_KEY, default=self.user_data.get(API_KEY, "")): str,
|
||||
vol.Optional(WSLINK, default=self.user_data.get(WSLINK, False)): bool,
|
||||
vol.Optional(DEV_DBG, default=self.user_data.get(DEV_DBG, False)): bool,
|
||||
}
|
||||
|
||||
self.sensors: dict[str, Any] = {
|
||||
|
|
@ -83,7 +97,7 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
|
||||
self.windy_data_schema = {
|
||||
vol.Optional(
|
||||
WINDY_API_KEY, default=self.windy_data[WINDY_API_KEY] or ""
|
||||
WINDY_API_KEY, default=self.windy_data.get(WINDY_API_KEY, "")
|
||||
): str,
|
||||
vol.Optional(WINDY_ENABLED, default=self.windy_data[WINDY_ENABLED]): bool
|
||||
or False,
|
||||
|
|
@ -93,12 +107,34 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
): bool or False,
|
||||
}
|
||||
|
||||
self.migrate_schema = {
|
||||
self.migrate_sensor_select = {
|
||||
vol.Required(SENSOR_TO_MIGRATE): vol.In(
|
||||
long_term_units_in_statistics_meta() or {}
|
||||
await self.load_sensors_to_migrate() or {}
|
||||
),
|
||||
}
|
||||
|
||||
self.migrate_unit_selection = {
|
||||
vol.Required(MIG_FROM): vol.In(self.unit_values),
|
||||
vol.Required(MIG_TO): vol.In(self.unit_values),
|
||||
vol.Optional("trigger_action", default=False): bool,
|
||||
}
|
||||
# "mm/d", "mm/h", "mm", "in/d", "in/h", "in"
|
||||
|
||||
async def load_sensors_to_migrate(self) -> dict[str, Any]:
|
||||
"""Load sensors to migrate."""
|
||||
|
||||
sensor_statistics = await long_term_units_in_statistics_meta(self.hass)
|
||||
|
||||
entity_registry = er.async_get(self.hass)
|
||||
sensors = entity_registry.entities.get_entries_for_config_entry_id(
|
||||
self.config_entry.entry_id
|
||||
)
|
||||
|
||||
return {
|
||||
sensor.entity_id: f"{sensor.name or sensor.original_name} (current settings: {sensor.unit_of_measurement}, longterm stats unit: {sensor_statistics.get(sensor.entity_id)})"
|
||||
for sensor in sensors
|
||||
if sensor.unique_id in {"rain", "daily_rain"}
|
||||
}
|
||||
|
||||
async def async_step_init(self, user_input=None):
|
||||
"""Manage the options - show menu first."""
|
||||
|
|
@ -110,7 +146,7 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
"""Manage basic options - credentials."""
|
||||
errors = {}
|
||||
|
||||
self._get_entry_data()
|
||||
await self._get_entry_data()
|
||||
|
||||
if user_input is None:
|
||||
return self.async_show_form(
|
||||
|
|
@ -147,7 +183,7 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
"""Manage windy options."""
|
||||
errors = {}
|
||||
|
||||
self._get_entry_data()
|
||||
await self._get_entry_data()
|
||||
|
||||
if user_input is None:
|
||||
return self.async_show_form(
|
||||
|
|
@ -160,7 +196,7 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
errors[WINDY_API_KEY] = "windy_key_required"
|
||||
return self.async_show_form(
|
||||
step_id="windy",
|
||||
data_schema=self.windy_data_schema,
|
||||
data_schema=vol.Schema(self.windy_data_schema),
|
||||
errors=errors,
|
||||
)
|
||||
|
||||
|
|
@ -175,15 +211,17 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
async def async_step_migration(self, user_input=None):
|
||||
"""Migrate sensors."""
|
||||
|
||||
# hj
|
||||
errors = {}
|
||||
|
||||
self._get_entry_data()
|
||||
data_schema = vol.Schema(self.migrate_sensor_select)
|
||||
data_schema.schema.update()
|
||||
|
||||
await self._get_entry_data()
|
||||
|
||||
if user_input is None:
|
||||
return self.async_show_form(
|
||||
step_id="migration",
|
||||
data_schema=vol.Schema(self.migrate_schema),
|
||||
data_schema=vol.Schema(self.migrate_sensor_select),
|
||||
errors=errors,
|
||||
description_placeholders={
|
||||
"migration_status": "-",
|
||||
|
|
@ -191,18 +229,116 @@ class ConfigOptionsFlowHandler(OptionsFlow):
|
|||
},
|
||||
)
|
||||
|
||||
if user_input.get("trigger_action"):
|
||||
# Akce se vykoná po zaškrtnutí
|
||||
count = await self.hass.async_add_executor_job(
|
||||
migrate_data, user_input.get(SENSOR_TO_MIGRATE)
|
||||
)
|
||||
self.selected_sensor = user_input.get(SENSOR_TO_MIGRATE)
|
||||
|
||||
return await self.async_step_migration_units()
|
||||
|
||||
async def async_step_migration_units(self, user_input=None):
|
||||
"""Migrate unit step."""
|
||||
|
||||
registry = er.async_get(self.hass)
|
||||
sensor_entry = registry.async_get(self.selected_sensor)
|
||||
sensor_stats = await long_term_units_in_statistics_meta(self.hass)
|
||||
|
||||
default_unit = sensor_entry.unit_of_measurement if sensor_entry else None
|
||||
|
||||
if default_unit not in self.unit_values:
|
||||
default_unit = self.unit_values[0]
|
||||
|
||||
data_schema = vol.Schema({
|
||||
vol.Required(MIG_FROM, default=default_unit): vol.In(self.unit_values),
|
||||
vol.Required(MIG_TO): vol.In(self.unit_values),
|
||||
vol.Optional("trigger_action", default=False): bool,
|
||||
})
|
||||
|
||||
if user_input is None:
|
||||
return self.async_show_form(
|
||||
step_id="migration",
|
||||
data_schema=vol.Schema(self.migrate_schema),
|
||||
step_id="migration_units",
|
||||
data_schema=data_schema,
|
||||
errors={},
|
||||
description_placeholders={
|
||||
"migration_sensor": sensor_entry.original_name,
|
||||
"migration_stats": sensor_stats.get(self.selected_sensor),
|
||||
},
|
||||
)
|
||||
|
||||
if user_input.get("trigger_action"):
|
||||
self.count = await migrate_data(
|
||||
self.hass,
|
||||
self.selected_sensor,
|
||||
user_input.get(MIG_FROM),
|
||||
user_input.get(MIG_TO),
|
||||
)
|
||||
|
||||
registry.async_update_entity(self.selected_sensor,
|
||||
unit_of_measurement=user_input.get(MIG_TO),
|
||||
)
|
||||
|
||||
state = self.hass.states.get(self.selected_sensor)
|
||||
if state:
|
||||
_LOGGER.info("State attributes before update: %s", state.attributes)
|
||||
attributes = dict(state.attributes)
|
||||
attributes["unit_of_measurement"] = user_input.get(MIG_TO)
|
||||
self.hass.states.async_set(self.selected_sensor, state.state, attributes)
|
||||
_LOGGER.info("State attributes after update: %s", attributes)
|
||||
|
||||
options = {**self.config_entry.options, "reload_sensor": self.selected_sensor}
|
||||
self.hass.config_entries.async_update_entry(self.config_entry, options=options)
|
||||
|
||||
await self.hass.config_entries.async_reload(self.config_entry.entry_id)
|
||||
|
||||
await self.hass.async_block_till_done()
|
||||
|
||||
_LOGGER.info("Migration complete for sensor %s: %s row updated, new measurement unit: %s, ",
|
||||
self.selected_sensor,
|
||||
self.count,
|
||||
user_input.get(MIG_TO),
|
||||
)
|
||||
|
||||
await self._get_entry_data()
|
||||
sensor_entry = er.async_get(self.hass).async_get(self.selected_sensor)
|
||||
sensor_stat = await self.load_sensors_to_migrate()
|
||||
|
||||
return self.async_show_form(
|
||||
step_id="migration_complete",
|
||||
data_schema=vol.Schema({}),
|
||||
errors={},
|
||||
description_placeholders={
|
||||
"migration_sensor": sensor_entry.unit_of_measurement,
|
||||
"migration_stats": sensor_stat.get(self.selected_sensor),
|
||||
"migration_count": self.count,
|
||||
},
|
||||
)
|
||||
|
||||
# retain windy data
|
||||
user_input.update(self.windy_data)
|
||||
|
||||
# retain user_data
|
||||
user_input.update(self.user_data)
|
||||
|
||||
# retain senors
|
||||
user_input.update(self.sensors)
|
||||
|
||||
return self.async_create_entry(title=DOMAIN, data=user_input)
|
||||
|
||||
async def async_step_migration_complete(self, user_input=None):
|
||||
"""Migration complete."""
|
||||
|
||||
errors = {}
|
||||
|
||||
await self._get_entry_data()
|
||||
sensor_entry = er.async_get(self.hass).async_get(self.selected_sensor)
|
||||
sensor_stat = await self.load_sensors_to_migrate()
|
||||
|
||||
if user_input is None:
|
||||
return self.async_show_form(
|
||||
step_id="migration_complete",
|
||||
data_schema=vol.Schema({}),
|
||||
errors=errors,
|
||||
description_placeholders={
|
||||
"migration_status": user_input.get(SENSOR_TO_MIGRATE),
|
||||
"migration_count": count,
|
||||
"migration_sensor": sensor_entry.unit_of_measurement,
|
||||
"migration_stats": sensor_stat.get(self.selected_sensor),
|
||||
"migration_count": self.count,
|
||||
},
|
||||
)
|
||||
|
||||
|
|
|
|||
Loading…