SchiZzA 5e4b02fd6e
fix: address remaining review findings across forwarders and utils
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
  reload the entry, so the cached copy left the diagnostics sensor reporting a
  stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
  `checked` alone let an unconfigured forwarder send a request that could only
  ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.

Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
  other value_fn. A bare `int()` raised on a garbage payload value, which
  `WeatherSensor.native_value` then logged with a full traceback on every push.
  Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).

Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
  to it from the webhook handler, so writing back the snapshot taken when the
  step opened silently rolled back any sensor discovered meanwhile.

Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.

Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
  failing the whole module import; unit-variant dedup degrades instead.

Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
  whose value is "drained", so the old key never matched and the raw state
  leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.

Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
2026-07-25 21:47:54 +02:00
SchiZzA 793ea1991a
feat(device): merge all entities into one shared device with station-type model
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.

The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.

No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.

Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-25 21:47:53 +02:00
SchiZzA 14466cbe60
fix(correctness): reload-window guards, rate-limit races, ecowitt flush, dt_util
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
  mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
  defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
  concurrent webhooks can no longer both pass the rate-limit check and double-send
  (which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
  platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
  config-entry reload (update_listener now skips reload for live-read flags
  SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().

Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-25 21:47:52 +02:00
SchiZzA 526d5e4f6e
test: reach 100% coverage of custom_components/sws12500
Add focused test modules and extend existing ones to cover every line of the
integration (1588 stmts, 0 missing; 295 tests):

- test_diagnostics.py: redaction + health_data fallback.
- test_binary_battery.py: binary_sensor platform setup / add_new + BatteryBinarySensor.
- test_staleness_legacy.py: warmup/threshold stale detection + legacy orphan issue.
- test_ecowitt_bridge.py: EcowittBridge parsing/discovery + EcoWittNativeSensor.
- test_health.py: HealthCoordinator (online/offline refresh, summary, ingress,
  forwarding, HTTP endpoint) + HealthDiagnosticSensor.
- test_received_ecowitt.py: received_ecowitt_data paths + received_data health branches.
- test_windy_more.py: duplicate (409) / rate-limit (429) / 3-strike disable.
- test_routes_more.py: RouteInfo.__str__, ingress observer, canonical resolve.
- test_utils_conv.py: to_int/to_float edge cases.
- config_flow: wslink_port_setup step + initial ecowitt flow.
- init: _check_stale time-interval callback.
- lifecycle: register_path idempotency (existing-dispatcher branch).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-25 21:47:51 +02:00