Coverage went from 54 of 107 upload parameters to all 107, adding roughly 34
entities. New families: Type5 lightning, Type6 water leak (CH1-7), Type8
particulate matter, Type10 CO2 and Type11 CO, plus the parameters missing from
existing families - absolute pressure, feels-like temperature, the 10-minute
average wind speed, and the per-channel probe type.
Device classes follow Home Assistant's own list (PM25, PM10, AQI, CO2, CO,
DISTANCE, ATMOSPHERIC_PRESSURE, WIND_SPEED, and binary MOISTURE for leaks), so
the readings work with statistics and unit conversion without template helpers.
Batteries were the trap. The API annotates two incompatible conventions -
"(Normal=1, Low battery=0)" and "(0~5) remark: 5 is full" - and mixing them up is
silent, because a level battery read as a flag reports "not low" for every level
above empty. Eight new binary batteries (t5lsbat, t6c1-7bat) and three new level
batteries (t8bat, t10bat, t11bat) are classified from the document, and
tests/test_wslink_api_coverage.py pins each one to the wording it came from.
Water leak and battery use opposite conventions in the same family (leak 1 means
wet, battery 0 means low), so `on_value` moved into the description and one
entity class now serves both instead of two that differ by a comparison.
`t1cn` was in the API but wired to nothing, so a disconnected outdoor probe kept
publishing its last readings. Gating it required fixing the gate first: an absent
connection flag was treated as "disconnected", which would have blanked
temperature, wind and rain outright on any firmware that omits `t1cn`. Absence is
now treated as no information, and only an explicit non-1 drops the readings.
The probe type (`t234cXtp`) decides whether a channel's humidity reading is air
humidity or soil moisture, which are different device classes. It is resolved
once, when the entity is created, because Home Assistant records the device class
in the entity registry; swapping the physical probe means reinstalling.
Two parameters are handled with a documented caveat: `inbat` is the only battery
whose scale the API does not state and stays a 0/1 flag, and `t5lst` has no unit
(the vendor example uses 9999) so it is read as minutes with 9999 meaning
"nothing recorded".
Also replaces the now-stale TODO block in const.py - it listed exactly these
sensors as unimplemented - and documents the complete coverage in the README.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
- Integrate aioecowitt to parse incoming weather station payloads and map sensors to the SWS pipeline.
- Add a new webhook endpoint at /weatherhub/{webhook_id} with support for dynamic route resolution.
- Expand battery binary sensor definitions and implement logic for dynamic entity creation.
- Bump version to 2.0.0-pre1.
- Introduce `to_int`/`to_float` helpers to safely handle None/blank payload values.
- Use the converters across weather/wslink sensor descriptions and simplify wind direction handling.
- Add low-battery binary sensor entities and definitions.