- manifest: add single_config_entry, integration_type "device", loggers
["aioecowitt"]; drop empty homekit/ssdp/zeroconf placeholders.
- Q10: raise ConfigEntryNotReady (not PlatformNotReady) when route registration
fails in async_setup_entry; drop the now-unused import.
- Q11: delete the ~105-line commented-out sqlite3 statistics-migration block in
utils.py (would have been blocking I/O in the event loop) and its dead import.
Deferred (with reason): quality_scale (needs a rule audit + quality_scale.yaml),
device-identifier 2-tuple and suggested_entity_id (entity-naming/identity changes,
to land with the planned integration rename), CoordinatorEntity generics in
sensor.py (would introduce a circular import - intentionally untyped).
Note: the health-probe protocol gate was reverted - the proxy add-on can front
WU/WSLink/Ecowitt, so polling must stay unconditional.
308 passing, 100% coverage; ruff clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
concurrent webhooks can no longer both pass the rate-limit check and double-send
(which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
config-entry reload (update_listener now skips reload for live-read flags
SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().
Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
After a config reload a new HealthCoordinator is created, but the sticky
/station/health route kept calling the previous (stale) instance. Add
Routes.rebind_handler() and call it from async_setup_entry's reload branch
so the endpoint always serves the current coordinator.
Also make _resolve_route() tolerant of requests without match_info/route/
resource instead of raising AttributeError.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
- Integrate aioecowitt to parse incoming weather station payloads and map sensors to the SWS pipeline.
- Add a new webhook endpoint at /weatherhub/{webhook_id} with support for dynamic route resolution.
- Expand battery binary sensor definitions and implement logic for dynamic entity creation.
- Bump version to 2.0.0-pre1.
- Introduce `to_int`/`to_float` helpers to safely handle None/blank payload values.
- Use the converters across weather/wslink sensor descriptions and simplify wind direction handling.
- Add low-battery binary sensor entities and definitions.
Use checked and checked_or to validate option and hass.data types,
remove unsafe typing.cast calls, simplify coordinator and entry_data
handling, and cache boolean option flags for Windy and Pocasí checks
- Register aiohttp webhook routes once and switch the active dispatcher handler on option changes
- Make the internal route registry method-aware (GET/POST) and improve enabled-route logging
- Fix OptionsFlow initialization by passing the config entry and using safe defaults for credentials
- Harden Windy resend by validating credentials early, auto-disabling the feature on invalid responses, and notifying the user
- Update translations for Windy credential validation errors
integration
- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
- Config flows and options validation
- Data reception and authentication
- Sensor platform setup and dynamic sensor addition
- Push integration with Pocasi.cz and Windy API
- Route dispatching and error handling
- Utilities, conversions, and translation functions
- Replace API key with station ID and password for authentication
- Change Windy API endpoint to v2 observation update
- Adapt data conversion for WSLink to Windy format
- Update config flow and translations accordingly
- Add detailed architecture overview in __init__.py
- Introduce shared runtime keys in data.py to avoid key conflicts
- Implement dual route dispatcher for webhook endpoint selection
- Enhance sensor platform for dynamic sensor addition without reloads
- Rename battery level "unknown" to "drained" with updated icons
- Improve utils.py with centralized helpers for remapping and discovery
- Update translations and strings for consistency
- Add typing and runtime checks with py_typecheck for config options and
incoming data
- Enhance authentication validation and error handling in data
coordinator
- Refactor Routes class with better dispatch logic and route
enabling/disabling
- Clean up async functions and improve logging consistency
- Add type hints and annotations throughout the integration
- Update manifest to include typecheck-runtime dependency
Includes new sensor connection status constants and mappings
Updates WeatherSensor to handle null data values
Switches temperature unit to Celsius for WSLink sensors
Refines heat and chill index calculations with unit conversions
Refactoring webhook switching.
Added routing management to automaticly update coordinator to avoid restarting HA on configuration change or on new sensor discovery.