- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
concurrent webhooks can no longer both pass the rate-limit check and double-send
(which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
config-entry reload (update_listener now skips reload for live-read flags
SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().
Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The suite predated the coordinator extraction and the typed runtime_data
migration: 5 modules failed to import and 18 tests failed.
- Import IncorrectDataError/WeatherDataUpdateCoordinator from .coordinator.
- Point received_data monkeypatch targets at custom_components.sws12500.coordinator.*
- Stub config entries with async_on_unload + runtime_data (SWSRuntimeData).
- Rewrite test_data, test_sensor_platform and test_integration_lifecycle off the
removed ENTRY_* hass.data keys onto runtime_data (route dispatcher reuse, ecowitt
POST route, no hass.data pop on unload, health first_refresh mocked).
- Update config_flow tests for the user menu (pws step) and the options menu
gaining wslink_port_setup.
- Fix VOCLevel.EXCELENT typo and stale t9 expectations (tuple battery list,
HCHO int coercion, connection-gated subset).
Result: 168 passed, 0 collection errors.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Include HTTP method in route keys and dispatch, and fix
Routes.show_enabled.
Update register_path to accept a HealthCoordinator and adjust router
stubs in tests. Update WindyPush tests to use response objects
(status/text)
and adapt related exception/notification expectations.
integration
- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
- Config flows and options validation
- Data reception and authentication
- Sensor platform setup and dynamic sensor addition
- Push integration with Pocasi.cz and Windy API
- Route dispatching and error handling
- Utilities, conversions, and translation functions