The WU/PWS platform derives both indices from temperature, humidity and wind
(value_from_data_fn=heat_index / chill_index), but the WSLink descriptions only
read the station's own t1heat / t1chill via value_fn=to_float. Stations that do
not report those fields still got both entities, because
_auto_enable_derived_sensors creates them as soon as the raw inputs arrive, so
they stayed Unavailable forever.
Add wslink_heat_index / wslink_chill_index: prefer the station's reading, compute
it otherwise. The conversions are the subtle part. The WSLink payload is metric
and both entities are declared in Celsius, while the NWS formulas are defined for
Fahrenheit, and chill_index converts the temperature but not the wind speed even
though its formula needs mph. So the temperature goes C -> F in, the wind m/s ->
mph, and the result F -> C back out. For the reported payload (6.2 C, 40 %,
30.6 m/s) that is -1.94 C; leaving the wind in m/s would have reported 0.34 C.
The native unit stays Celsius on purpose: switching it to Fahrenheit to match the
WU platform would misread the values of stations that do send t1heat / t1chill.
Also guard on missing temperature/humidity/wind before delegating, so a payload
without those fields no longer logs an error on every push.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
- manifest: add single_config_entry, integration_type "device", loggers
["aioecowitt"]; drop empty homekit/ssdp/zeroconf placeholders.
- Q10: raise ConfigEntryNotReady (not PlatformNotReady) when route registration
fails in async_setup_entry; drop the now-unused import.
- Q11: delete the ~105-line commented-out sqlite3 statistics-migration block in
utils.py (would have been blocking I/O in the event loop) and its dead import.
Deferred (with reason): quality_scale (needs a rule audit + quality_scale.yaml),
device-identifier 2-tuple and suggested_entity_id (entity-naming/identity changes,
to land with the planned integration rename), CoordinatorEntity generics in
sensor.py (would introduce a circular import - intentionally untyped).
Note: the health-probe protocol gate was reverted - the proxy add-on can front
WU/WSLink/Ecowitt, so polling must stay unconditional.
308 passing, 100% coverage; ruff clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
concurrent webhooks can no longer both pass the rate-limit check and double-send
(which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
config-entry reload (update_listener now skips reload for live-read flags
SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().
Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
extra_state_attributes (readable by any HA user). public_health_snapshot()
strips internal network details (source IP, internal URLs, raw add-on status);
full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).
i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.
Tests: 300 passing, 100% coverage maintained; basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The azimut value_from_data_fn now passes dir.get(WIND_DIR) (typed Any | None),
which tripped basedpyright reportArgumentType against the float-only signature.
The body already coerces via to_float() and handles None, so widen the
annotation to match the real inputs (raw str payload, float, or None).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- wind_dir_to_text: treat 0/missing direction as None (calm) so a missing
wind direction no longer renders as North; azimut lambdas pass None too.
- windy: log response status (was logging an un-awaited coroutine method);
count "unexpected response" toward the disable threshold even when logging
is off.
- pocasi: disable threshold >3 -> >=3 to match Windy's 3-strike behavior.
- ecowitt: always attach device_info to native sensors, including unknown
sensor types (previously left orphaned without a device).
- const: stop remapping WSLink connection flags (t1cn/t234cXcn) into the
payload; they had no entity and leaked ghost *_connection keys into data
and persisted SENSORS_TO_LOAD. Gating uses the raw keys and is unaffected.
- config_flow: fix WSLink port fallback typo 433 -> 443; drop mutable default
argument on async_step_init.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
Updated config flow's initial setup.
Ecowitt stations does not require `API_ID` and `API_KEY`, so we need to
separate Ecowitt setup from PWS/WSLink setup.
- Introduce `to_int`/`to_float` helpers to safely handle None/blank payload values.
- Use the converters across weather/wslink sensor descriptions and simplify wind direction handling.
- Add low-battery binary sensor entities and definitions.
- Add detailed architecture overview in __init__.py
- Introduce shared runtime keys in data.py to avoid key conflicts
- Implement dual route dispatcher for webhook endpoint selection
- Enhance sensor platform for dynamic sensor addition without reloads
- Rename battery level "unknown" to "drained" with updated icons
- Improve utils.py with centralized helpers for remapping and discovery
- Update translations and strings for consistency
- Add typing and runtime checks with py_typecheck for config options and
incoming data
- Enhance authentication validation and error handling in data
coordinator
- Refactor Routes class with better dispatch logic and route
enabling/disabling
- Clean up async functions and improve logging consistency
- Add type hints and annotations throughout the integration
- Update manifest to include typecheck-runtime dependency
Fixed computing Heat and Chill index in cases that outside senosor
battery is drained and station stop sending data for outside temp,
humidity and wind.
Adds an outside battery sensor to the integration, providing information about the battery level of the outdoor sensor.
This includes:
- Mapping the `t1bat` WSLink item to the `OUTSIDE_BATTERY` sensor.
- Implementing logic to convert the battery level to a human-readable text representation and a corresponding icon.
- Updates precipitation to intensity and fixes data type of battery level
Refactors battery level representation by using enum instead of string.
Improves battery level display by adding an icon representation.
Changes const BATLEVEL to BATTERY_LEVEL.
Fixes#62
Fixes rainfall unit inconsistency
Updates daily rain sensor to use consistent measurement units and corrects device class and suggested unit.
Fixes#62
Adds database path constant and data migration function
Defines DATABASE_PATH constant for database file location
Introduces migrate_data function to update unit of measurement in long statistics.
Adds sensor migration feature
Introduces a migration step for sensor statistics
Updates schema and translations to support migration
Fixes data migration from mm/d to mm
Includes new sensor connection status constants and mappings
Updates WeatherSensor to handle null data values
Switches temperature unit to Celsius for WSLink sensors
Refines heat and chill index calculations with unit conversions
Refactoring webhook switching.
Added routing management to automaticly update coordinator to avoid restarting HA on configuration change or on new sensor discovery.
Fix chill index formula as suggested by @facko79.
Chill index is computed only for temperatures less then 10°C (50°F). Otherwise real temperature is returned.
- A new constant `WIND_AZIMUT` is added to allow creating a wind direction sensor that returns a text value from `UnitOfDir` instead of just a numeric degree value.
- The wind direction sensor entity now optionally creates both a numeric wind direction sensor using `WIND_DIR` and a text-based azimuth sensor using `WIND_AZIMUT`. If the numeric one is enabled, the text one will also be added.
So in summary, these changes improve the usability of wind data by adding a more human-readable text version alongside the existing numeric version.