Extract WSLink add-on probe and treat expected network errors and
NoURLAvailableError as "offline" instead of raising. Log unexpected
errors and avoid raising ConfigEntryNotReady from diagnostics probes.
Add tests for probe robustness, add additional sensitive purge keys,
and fix config_flow host fallback handling.
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.
The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.
No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.
Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The health model only knew "wu"/"wslink", so with an Ecowitt setup the
active_protocol / integration_status fell back to "PWS/WU" even while Ecowitt data
was flowing.
- Replace _protocol_name() with _configured_protocol() which returns
wu / wslink / ecowitt (legacy endpoint takes precedence; ecowitt-only -> ecowitt).
- _refresh_summary: treat "ecowitt" as a real accepted protocol (active_protocol and
online_<proto> now track it); the WU-vs-WSLink mismatch -> degraded check is scoped
to the legacy pair so coexisting Ecowitt is never falsely degraded.
- Add the "ecowitt" / "online_ecowitt" entity states to strings/en/cs.
310 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
extra_state_attributes (readable by any HA user). public_health_snapshot()
strips internal network details (source IP, internal URLs, raw add-on status);
full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).
i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.
Tests: 300 passing, 100% coverage maintained; basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The /station/health route is registered directly on the aiohttp router, so HA's
auth middleware only flags requests without blocking them - the endpoint was
reachable unauthenticated and returned the full health snapshot.
- health_status now requires HA authentication (bearer token or signed request)
via KEY_AUTHENTICATED and returns 401 otherwise.
- Mask the Ecowitt webhook id (the endpoint's only credential) in last_ingress
paths via _sanitize_path, so it never enters the snapshot exposed by the health
endpoint or the diagnostics download.
- Redact ECOWITT_WEBHOOK_ID in diagnostics.
- Compare the Ecowitt webhook id in constant time (hmac.compare_digest), matching
the WU/WSLink credential checks.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>