- Reject blank or whitespace-only PWS credentials in both the config flow and
the options flow. INVALID_CREDENTIALS only held placeholder strings, so an
empty API ID or key passed validation, the entry was created, and
_validate_credentials then rejected every incoming packet.
- Fall back to "UNKNOWN" host/port when get_url raises NoURLAvailableError.
The values are shown as Ecowitt setup instructions only, so an unresolvable
Home Assistant URL must not make the step unreachable.
- Catch TimeoutError alongside ClientError in the Windy and Pocasi push paths.
A timeout is not a ClientError and used to escape into the webhook handler,
answering the station with HTTP 500 even though the measured data was
already stored.
- Add regression tests for all three and pin that 0-5 battery descriptions
really reach the WSLink sensor platform.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
Extract WSLink add-on probe and treat expected network errors and
NoURLAvailableError as "offline" instead of raising. Log unexpected
errors and avoid raising ConfigEntryNotReady from diagnostics probes.
Add tests for probe robustness, add additional sensitive purge keys,
and fix config_flow host fallback handling.
API_KEY, WINDY_STATION_PWD and POCASI_CZ_API_KEY now use a password TextSelector so
the values are masked in the UI. Field keys are unchanged, so stored options and the
flow contract are unaffected.
308 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- wind_dir_to_text: treat 0/missing direction as None (calm) so a missing
wind direction no longer renders as North; azimut lambdas pass None too.
- windy: log response status (was logging an un-awaited coroutine method);
count "unexpected response" toward the disable threshold even when logging
is off.
- pocasi: disable threshold >3 -> >=3 to match Windy's 3-strike behavior.
- ecowitt: always attach device_info to native sensors, including unknown
sensor types (previously left orphaned without a device).
- const: stop remapping WSLink connection flags (t1cn/t234cXcn) into the
payload; they had no entity and leaked ghost *_connection keys into data
and persisted SENSORS_TO_LOAD. Gating uses the raw keys and is unaffected.
- config_flow: fix WSLink port fallback typo 433 -> 443; drop mutable default
argument on async_step_init.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
Updated config flow's initial setup.
Ecowitt stations does not require `API_ID` and `API_KEY`, so we need to
separate Ecowitt setup from PWS/WSLink setup.
- Register aiohttp webhook routes once and switch the active dispatcher handler on option changes
- Make the internal route registry method-aware (GET/POST) and improve enabled-route logging
- Fix OptionsFlow initialization by passing the config entry and using safe defaults for credentials
- Harden Windy resend by validating credentials early, auto-disabling the feature on invalid responses, and notifying the user
- Update translations for Windy credential validation errors
integration
- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
- Config flows and options validation
- Data reception and authentication
- Sensor platform setup and dynamic sensor addition
- Push integration with Pocasi.cz and Windy API
- Route dispatching and error handling
- Utilities, conversions, and translation functions
- Replace API key with station ID and password for authentication
- Change Windy API endpoint to v2 observation update
- Adapt data conversion for WSLink to Windy format
- Update config flow and translations accordingly
- Add typing and runtime checks with py_typecheck for config options and
incoming data
- Enhance authentication validation and error handling in data
coordinator
- Refactor Routes class with better dispatch logic and route
enabling/disabling
- Clean up async functions and improve logging consistency
- Add type hints and annotations throughout the integration
- Update manifest to include typecheck-runtime dependency
- Keep OptionsFlow state in sync by building defaults from entry data + options
- Store the config entry on the coordinator for consistent access
- Make route registry method-aware and switch handlers by url_path with
awarness of POST/GET method.
- Fixed an issue, when on config update needs restart of HomeAssistant
to reload integration.
* Fixing error when Windy was not set correctly.
Fixed an issue when integration fails to send data to Windy and crashed,
so no data was accepted from station.
Windy resend is disabled on misconfiguration detect.
* Fixed WSLink bool in resend function.
- Replace API key with station ID and password for Windy data push
- Change Windy update URL and add authorization header
- Update config flow and constants to support new credentials
- Adjust data mapping for WSLink compatibility
- Change WSLink endpoint HTTP method to POST
Introduce new config step for Počasí Meteo CZ with validation and UI
schema. Define related constants and translation keys for setting up
data forwarding.
Removes the unused import of `utils` to improve code cleanliness and avoid potential namespace conflicts.
Removed 'migration' from menu as it is intended to use in later version.
Implements a user interface to migrate units for rain sensors including migration of historic data via statistics.
This provides the user with the ability to correct rain units, if they have been set incorrectly.
Includes UI to select sensor and units, as well as trigger migration.
Fixes#62
Fixes rainfall unit inconsistency
Updates daily rain sensor to use consistent measurement units and corrects device class and suggested unit.
Fixes#62
Adds database path constant and data migration function
Defines DATABASE_PATH constant for database file location
Introduces migrate_data function to update unit of measurement in long statistics.
Adds sensor migration feature
Introduces a migration step for sensor statistics
Updates schema and translations to support migration
Fixes data migration from mm/d to mm
Refactoring webhook switching.
Added routing management to automaticly update coordinator to avoid restarting HA on configuration change or on new sensor discovery.