SchiZzA 80c944fc5a
feat(device): merge all entities into one shared device with station-type model
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.

The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.

No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.

Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 23:37:11 +02:00
SchiZzA 3fdebc6f20
feat(ecowitt): dedupe unit-variant sensors and translate common native ones
Two long-standing rough edges with Ecowitt running alongside the SWS device:

- Dedup (#1): aioecowitt emits both metric and imperial sensors per quantity
  (tempc/tempf, rainratemm/rainratein, ...). Only the imperial twin is mapped to the
  SWS sensors, so the metric twin (and other unmapped extras) showed up as duplicate
  native entities. _on_new_sensor now skips a key whose unit-variant twin is already
  mapped or already created (twin groups derived from aioecowitt's SENSOR_MAP). HA
  converts units via device_class, so a single variant suffices.
- Translation (#2): native sensors used the raw English aioecowitt name. Common
  single-instance families (rain rate / hourly / event / 24h / weekly / monthly /
  yearly / total rain, absolute pressure, feels-like, indoor dew point, CO2) now use
  curated translation_keys (added to strings/en/cs); long-tail / multi-channel
  sensors keep the English name fallback.
- Also add the imperial RAIN_RATE_INCHES / RAIN_COUNT_INCHES to STYPE_TO_HA so those
  native rain sensors get a device class and unit.

Device unification (one "WeatherHub" device + station-type sensor) stays for the
rename round, as agreed.

314 passing, 100% coverage; ruff + basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 22:55:58 +02:00
SchiZzA 72c383ffba
fix(health): reflect Ecowitt as a protocol in the diagnostics summary
The health model only knew "wu"/"wslink", so with an Ecowitt setup the
active_protocol / integration_status fell back to "PWS/WU" even while Ecowitt data
was flowing.

- Replace _protocol_name() with _configured_protocol() which returns
  wu / wslink / ecowitt (legacy endpoint takes precedence; ecowitt-only -> ecowitt).
- _refresh_summary: treat "ecowitt" as a real accepted protocol (active_protocol and
  online_<proto> now track it); the WU-vs-WSLink mismatch -> degraded check is scoped
  to the legacy pair so coexisting Ecowitt is never falsely degraded.
- Add the "ecowitt" / "online_ecowitt" entity states to strings/en/cs.

310 passing, 100% coverage; ruff + basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 21:47:05 +02:00
SchiZzA df8e503d2c
chore(quality): manifest keys, ConfigEntryNotReady, remove dead sqlite code
- manifest: add single_config_entry, integration_type "device", loggers
  ["aioecowitt"]; drop empty homekit/ssdp/zeroconf placeholders.
- Q10: raise ConfigEntryNotReady (not PlatformNotReady) when route registration
  fails in async_setup_entry; drop the now-unused import.
- Q11: delete the ~105-line commented-out sqlite3 statistics-migration block in
  utils.py (would have been blocking I/O in the event loop) and its dead import.

Deferred (with reason): quality_scale (needs a rule audit + quality_scale.yaml),
device-identifier 2-tuple and suggested_entity_id (entity-naming/identity changes,
to land with the planned integration rename), CoordinatorEntity generics in
sensor.py (would introduce a circular import - intentionally untyped).
Note: the health-probe protocol gate was reverted - the proxy add-on can front
WU/WSLink/Ecowitt, so polling must stay unconditional.

308 passing, 100% coverage; ruff clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 19:01:32 +02:00
SchiZzA 418d0c7546
fix(security): harden forwarders, cap native ecowitt entities, reject empty creds
- S8: received_data now rejects empty configured credentials (IncorrectDataError)
  and present-but-empty incoming credentials (HTTPUnauthorized) instead of relying
  solely on the config flow. Credential validation extracted into
  _validate_credentials() (also resolves the C901 complexity warning and unifies
  the WU/WSLink branches).
- S6: cap auto-created native Ecowitt entities (MAX_NATIVE_ECOWITT_SENSORS) to bound
  entity-registry growth from a fabricated multi-key payload.
- S5: store only the exception class name in Windy/Pocasi last_error (surfaced via
  entity attributes; str(ex) could embed the request URL).
- S7: verified safe - the native-sensor INFO log is parametrized (%s), so no
  format-string injection; left as-is.

308 passing, 100% coverage; ruff + basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 18:48:50 +02:00
SchiZzA 038d2459b9
fix(correctness): reload-window guards, rate-limit races, ecowitt flush, dt_util
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
  mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
  defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
  concurrent webhooks can no longer both pass the rate-limit check and double-send
  (which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
  platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
  config-entry reload (update_listener now skips reload for live-read flags
  SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().

Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 18:32:00 +02:00
SchiZzA 1fe4d6da45
fix(security)+i18n: stop health-attribute leak, mask secrets in logs, sync translations
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
  extra_state_attributes (readable by any HA user). public_health_snapshot()
  strips internal network details (source IP, internal URLs, raw add-on status);
  full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).

i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
  the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
  windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
  keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
  pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
  options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.

Tests: 300 passing, 100% coverage maintained; basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 18:08:34 +02:00
SchiZzA bf6a02c5b3
fix(security): authenticate health endpoint and stop webhook-id leak
The /station/health route is registered directly on the aiohttp router, so HA's
auth middleware only flags requests without blocking them - the endpoint was
reachable unauthenticated and returned the full health snapshot.

- health_status now requires HA authentication (bearer token or signed request)
  via KEY_AUTHENTICATED and returns 401 otherwise.
- Mask the Ecowitt webhook id (the endpoint's only credential) in last_ingress
  paths via _sanitize_path, so it never enters the snapshot exposed by the health
  endpoint or the diagnostics download.
- Redact ECOWITT_WEBHOOK_ID in diagnostics.
- Compare the Ecowitt webhook id in constant time (hmac.compare_digest), matching
  the WU/WSLink credential checks.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 13:42:56 +02:00
SchiZzA b3aec61fc2
test: reach 100% coverage of custom_components/sws12500
Add focused test modules and extend existing ones to cover every line of the
integration (1588 stmts, 0 missing; 295 tests):

- test_diagnostics.py: redaction + health_data fallback.
- test_binary_battery.py: binary_sensor platform setup / add_new + BatteryBinarySensor.
- test_staleness_legacy.py: warmup/threshold stale detection + legacy orphan issue.
- test_ecowitt_bridge.py: EcowittBridge parsing/discovery + EcoWittNativeSensor.
- test_health.py: HealthCoordinator (online/offline refresh, summary, ingress,
  forwarding, HTTP endpoint) + HealthDiagnosticSensor.
- test_received_ecowitt.py: received_ecowitt_data paths + received_data health branches.
- test_windy_more.py: duplicate (409) / rate-limit (429) / 3-strike disable.
- test_routes_more.py: RouteInfo.__str__, ingress observer, canonical resolve.
- test_utils_conv.py: to_int/to_float edge cases.
- config_flow: wslink_port_setup step + initial ecowitt flow.
- init: _check_stale time-interval callback.
- lifecycle: register_path idempotency (existing-dispatcher branch).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 13:23:34 +02:00
SchiZzA 50d0e9fae7
test: align suite with v2.0 runtime_data architecture
The suite predated the coordinator extraction and the typed runtime_data
migration: 5 modules failed to import and 18 tests failed.

- Import IncorrectDataError/WeatherDataUpdateCoordinator from .coordinator.
- Point received_data monkeypatch targets at custom_components.sws12500.coordinator.*
- Stub config entries with async_on_unload + runtime_data (SWSRuntimeData).
- Rewrite test_data, test_sensor_platform and test_integration_lifecycle off the
  removed ENTRY_* hass.data keys onto runtime_data (route dispatcher reuse, ecowitt
  POST route, no hass.data pop on unload, health first_refresh mocked).
- Update config_flow tests for the user menu (pws step) and the options menu
  gaining wslink_port_setup.
- Fix VOCLevel.EXCELENT typo and stale t9 expectations (tuple battery list,
  HCHO int coercion, connection-gated subset).

Result: 168 passed, 0 collection errors.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 12:51:52 +02:00
SchiZzA 21dfa61cd5
Add HCHO / VOC air-quality sensors (T9 module)
Support the WSLink t9 air-quality module:
  - t9hcho (formaldehyde, ppb),
  - t9voclv (VOC level 1-5 -> ENUM state)
  - t9bat (0-5 battery -> percentage).

  The t9hcho/t9voclv/t9bat values are dropped when
  t9cn reports the module as disconnected,
  so no empty entities are created.

  - const: HCHO/VOC/T9_BATTERY keys, VOCLevel enum +
  VOC_LEVEL_MAP, BATTERY_NON_BINARY, CONNECTION_GATED_SENSORS,
  REMAP_WSLINK_ITEMS entries
  - utils: voc_level_to_text(),
  battery_5step_to_pct(), connection gating
  - sensors_wslink: HCHO / VOC / T9_BATTERY entity
  descriptions
  - translations (en, cs): hcho, voc (+ states),
  t9_battery
  - tests: tests/conftest.py +
  tests/test_t9_air_quality.py
2026-05-24 22:19:30 +02:00
SchiZzA f0554573ce
Make routes method-aware and update related tests
Include HTTP method in route keys and dispatch, and fix
Routes.show_enabled.
Update register_path to accept a HealthCoordinator and adjust router
stubs in tests. Update WindyPush tests to use response objects
(status/text)
and adapt related exception/notification expectations.
2026-03-04 07:53:26 +01:00
SchiZzA 1bbeab1ffe
Add health diagnostic sensor and extensive tests for sws12500
integration

- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
  - Config flows and options validation
  - Data reception and authentication
  - Sensor platform setup and dynamic sensor addition
  - Push integration with Pocasi.cz and Windy API
  - Route dispatching and error handling
  - Utilities, conversions, and translation functions
2026-02-21 11:29:40 +01:00