7 Commits (8b38db69515cfefb72f885dfa324f90a522bee7c)

Author SHA1 Message Date
SchiZzA 793ea1991a
feat(device): merge all entities into one shared device with station-type model
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.

The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.

No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.

Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-25 21:47:53 +02:00
SchiZzA 4fa86a5bb0
fix(security)+i18n: stop health-attribute leak, mask secrets in logs, sync translations
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
  extra_state_attributes (readable by any HA user). public_health_snapshot()
  strips internal network details (source IP, internal URLs, raw add-on status);
  full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).

i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
  the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
  windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
  keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
  pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
  options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.

Tests: 300 passing, 100% coverage maintained; basedpyright clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-25 21:47:52 +02:00
SchiZzA 6363351d9c
fix: coordinator reuse, route dispatcher, binary sensor translations & test suite alignment
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
  creating a new one; routes keep pointing to the same coordinator, so entities
  stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
  (auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
  all aiohttp routes are registered once and an internal dispatcher decides which
  handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator

- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
  `WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
  not `entity.sensor.*`

- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
2026-07-25 21:47:50 +02:00
SchiZzA dc69d20c3b
Add Ecowitt compatibility and deprecate legacy battery sensors. 2026-07-25 21:47:48 +02:00
SchiZzA affd26e7a5
Add health diagnostics coordinator and routing snapshot
Track ingress/forwarding status, expose detailed health sensors and translations, and include redacted diagnostics data.
2026-07-25 21:47:47 +02:00
SchiZzA 970828320b
Add multiple health sensors and device info
Introduce HealthSensorEntityDescription and a tuple of sensor
descriptions for integration status, source IP, base URL and addon
response. Instantiate one HealthDiagnosticSensor per description in
async_setup_entry. Update HealthDiagnosticSensor to accept a
description, derive unique_id from description.key and add a cached
device_info returning a SERVICE-type device. Adjust imports.
2026-07-25 21:47:46 +02:00
SchiZzA 0060369d8a
Add health diagnostic sensor and extensive tests for sws12500
integration

- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
  - Config flows and options validation
  - Data reception and authentication
  - Sensor platform setup and dynamic sensor addition
  - Push integration with Pocasi.cz and Windy API
  - Route dispatching and error handling
  - Utilities, conversions, and translation functions
2026-07-25 21:45:08 +02:00