Coverage went from 54 of 107 upload parameters to all 107, adding roughly 34
entities. New families: Type5 lightning, Type6 water leak (CH1-7), Type8
particulate matter, Type10 CO2 and Type11 CO, plus the parameters missing from
existing families - absolute pressure, feels-like temperature, the 10-minute
average wind speed, and the per-channel probe type.
Device classes follow Home Assistant's own list (PM25, PM10, AQI, CO2, CO,
DISTANCE, ATMOSPHERIC_PRESSURE, WIND_SPEED, and binary MOISTURE for leaks), so
the readings work with statistics and unit conversion without template helpers.
Batteries were the trap. The API annotates two incompatible conventions -
"(Normal=1, Low battery=0)" and "(0~5) remark: 5 is full" - and mixing them up is
silent, because a level battery read as a flag reports "not low" for every level
above empty. Eight new binary batteries (t5lsbat, t6c1-7bat) and three new level
batteries (t8bat, t10bat, t11bat) are classified from the document, and
tests/test_wslink_api_coverage.py pins each one to the wording it came from.
Water leak and battery use opposite conventions in the same family (leak 1 means
wet, battery 0 means low), so `on_value` moved into the description and one
entity class now serves both instead of two that differ by a comparison.
`t1cn` was in the API but wired to nothing, so a disconnected outdoor probe kept
publishing its last readings. Gating it required fixing the gate first: an absent
connection flag was treated as "disconnected", which would have blanked
temperature, wind and rain outright on any firmware that omits `t1cn`. Absence is
now treated as no information, and only an explicit non-1 drops the readings.
The probe type (`t234cXtp`) decides whether a channel's humidity reading is air
humidity or soil moisture, which are different device classes. It is resolved
once, when the entity is created, because Home Assistant records the device class
in the entity registry; swapping the physical probe means reinstalling.
Two parameters are handled with a documented caveat: `inbat` is the only battery
whose scale the API does not state and stays a 0/1 flag, and `t5lst` has no unit
(the vendor example uses 9999) so it is read as minutes with 9999 meaning
"nothing recorded".
Also replaces the now-stale TODO block in const.py - it listed exactly these
sensors as unimplemented - and documents the complete coverage in the README.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
Add POCASI_CZ_MAX_RETRIES and map HTTP status codes to explicit send
outcomes. Use the status (not the empty body) to classify sends as
"ok", "auth_error", or "unexpected_response". Introduce _disable_pocasi
to persistently turn off resending and record errors. Count unexpected
responses and disable resends after the retry limit; adjust client-error
handling to reuse the same disable logic. Update tests and config flow
expectations to match the new behavior.
Extract WSLink add-on probe and treat expected network errors and
NoURLAvailableError as "offline" instead of raising. Log unexpected
errors and avoid raising ConfigEntryNotReady from diagnostics probes.
Add tests for probe robustness, add additional sensitive purge keys,
and fix config_flow host fallback handling.
- wind_dir_to_text: treat 0/missing direction as None (calm) so a missing
wind direction no longer renders as North; azimut lambdas pass None too.
- windy: log response status (was logging an un-awaited coroutine method);
count "unexpected response" toward the disable threshold even when logging
is off.
- pocasi: disable threshold >3 -> >=3 to match Windy's 3-strike behavior.
- ecowitt: always attach device_info to native sensors, including unknown
sensor types (previously left orphaned without a device).
- const: stop remapping WSLink connection flags (t1cn/t234cXcn) into the
payload; they had no entity and leaked ghost *_connection keys into data
and persisted SENSORS_TO_LOAD. Gating uses the raw keys and is unaffected.
- config_flow: fix WSLink port fallback typo 433 -> 443; drop mutable default
argument on async_step_init.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
Updated config flow's initial setup.
Ecowitt stations does not require `API_ID` and `API_KEY`, so we need to
separate Ecowitt setup from PWS/WSLink setup.
- Integrate aioecowitt to parse incoming weather station payloads and map sensors to the SWS pipeline.
- Add a new webhook endpoint at /weatherhub/{webhook_id} with support for dynamic route resolution.
- Expand battery binary sensor definitions and implement logic for dynamic entity creation.
- Bump version to 2.0.0-pre1.
- Extend constants and WSLink key remapping for channels 3–8 (temp, humidity, battery and connection)
- Add new WSLink sensor entity descriptions for the extra channel readings
- Update English translations for the newly added channel sensors and battery states
- Add WINDY_MAX_RETRIES constant and use it consistently when deciding to disable resending
- Refactor Windy response verification to rely on HTTP status codes per stations.windy.com API
- Improve error handling for missing password, duplicate payloads and rate limiting
- Enhance retry logging and disable Windy resend via persistent notification on repeated failures
integration
- Introduce HealthDiagnosticSensor for device health status reporting
- Add new constants and data keys for health sensor integration
- Wire health_sensor module into sensor platform setup
- Refactor sensor descriptions to improve derived sensor handling
- Implement pytest fixtures and comprehensive tests covering:
- Config flows and options validation
- Data reception and authentication
- Sensor platform setup and dynamic sensor addition
- Push integration with Pocasi.cz and Windy API
- Route dispatching and error handling
- Utilities, conversions, and translation functions
- Add detailed architecture overview in __init__.py
- Introduce shared runtime keys in data.py to avoid key conflicts
- Implement dual route dispatcher for webhook endpoint selection
- Enhance sensor platform for dynamic sensor addition without reloads
- Rename battery level "unknown" to "drained" with updated icons
- Improve utils.py with centralized helpers for remapping and discovery
- Update translations and strings for consistency
- Replace API key with station ID and password for Windy data push
- Change Windy update URL and add authorization header
- Update config flow and constants to support new credentials
- Adjust data mapping for WSLink compatibility
- Change WSLink endpoint HTTP method to POST
Introduce new config step for Počasí Meteo CZ with validation and UI
schema. Define related constants and translation keys for setting up
data forwarding.
Adds the Wet Bulb Globe Temperature (WBGT) sensor to the integration, pulling data via the WSLink API.
Corrects the state class for rain and wind direction.
Adds support for displaying indoor console and channel 2 battery levels as sensors.
Updates sensor logic to use a common list to determine icon representation
Fixes#74
Adds an outside battery sensor to the integration, providing information about the battery level of the outdoor sensor.
This includes:
- Mapping the `t1bat` WSLink item to the `OUTSIDE_BATTERY` sensor.
- Implementing logic to convert the battery level to a human-readable text representation and a corresponding icon.
- Updates precipitation to intensity and fixes data type of battery level
Adds hourly, weekly, monthly, and yearly rain sensors to the integration for WSLink connection.
The units of measurement are corrected for the rain sensor, now displaying millimeters per hour as the station is sending data in mm/h for 'rain' sensor. And cumulative precipitation is in millimeters.
Also includes translations for the new sensors.
Fixes#62
Fixes rainfall unit inconsistency
Updates daily rain sensor to use consistent measurement units and corrects device class and suggested unit.
Fixes#62
Adds database path constant and data migration function
Defines DATABASE_PATH constant for database file location
Introduces migrate_data function to update unit of measurement in long statistics.
Adds sensor migration feature
Introduces a migration step for sensor statistics
Updates schema and translations to support migration
Fixes data migration from mm/d to mm
Includes new sensor connection status constants and mappings
Updates WeatherSensor to handle null data values
Switches temperature unit to Celsius for WSLink sensors
Refines heat and chill index calculations with unit conversions