Coverage went from 54 of 107 upload parameters to all 107, adding roughly 34
entities. New families: Type5 lightning, Type6 water leak (CH1-7), Type8
particulate matter, Type10 CO2 and Type11 CO, plus the parameters missing from
existing families - absolute pressure, feels-like temperature, the 10-minute
average wind speed, and the per-channel probe type.
Device classes follow Home Assistant's own list (PM25, PM10, AQI, CO2, CO,
DISTANCE, ATMOSPHERIC_PRESSURE, WIND_SPEED, and binary MOISTURE for leaks), so
the readings work with statistics and unit conversion without template helpers.
Batteries were the trap. The API annotates two incompatible conventions -
"(Normal=1, Low battery=0)" and "(0~5) remark: 5 is full" - and mixing them up is
silent, because a level battery read as a flag reports "not low" for every level
above empty. Eight new binary batteries (t5lsbat, t6c1-7bat) and three new level
batteries (t8bat, t10bat, t11bat) are classified from the document, and
tests/test_wslink_api_coverage.py pins each one to the wording it came from.
Water leak and battery use opposite conventions in the same family (leak 1 means
wet, battery 0 means low), so `on_value` moved into the description and one
entity class now serves both instead of two that differ by a comparison.
`t1cn` was in the API but wired to nothing, so a disconnected outdoor probe kept
publishing its last readings. Gating it required fixing the gate first: an absent
connection flag was treated as "disconnected", which would have blanked
temperature, wind and rain outright on any firmware that omits `t1cn`. Absence is
now treated as no information, and only an explicit non-1 drops the readings.
The probe type (`t234cXtp`) decides whether a channel's humidity reading is air
humidity or soil moisture, which are different device classes. It is resolved
once, when the entity is created, because Home Assistant records the device class
in the entity registry; swapping the physical probe means reinstalling.
Two parameters are handled with a documented caveat: `inbat` is the only battery
whose scale the API does not state and stays a 0/1 flag, and `t5lst` has no unit
(the vendor example uses 9999) so it is read as minutes with 9999 meaning
"nothing recorded".
Also replaces the now-stale TODO block in const.py - it listed exactly these
sensors as unimplemented - and documents the complete coverage in the README.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
Two long-standing rough edges with Ecowitt running alongside the SWS device:
- Dedup (#1): aioecowitt emits both metric and imperial sensors per quantity
(tempc/tempf, rainratemm/rainratein, ...). Only the imperial twin is mapped to the
SWS sensors, so the metric twin (and other unmapped extras) showed up as duplicate
native entities. _on_new_sensor now skips a key whose unit-variant twin is already
mapped or already created (twin groups derived from aioecowitt's SENSOR_MAP). HA
converts units via device_class, so a single variant suffices.
- Translation (#2): native sensors used the raw English aioecowitt name. Common
single-instance families (rain rate / hourly / event / 24h / weekly / monthly /
yearly / total rain, absolute pressure, feels-like, indoor dew point, CO2) now use
curated translation_keys (added to strings/en/cs); long-tail / multi-channel
sensors keep the English name fallback.
- Also add the imperial RAIN_RATE_INCHES / RAIN_COUNT_INCHES to STYPE_TO_HA so those
native rain sensors get a device class and unit.
Device unification (one "WeatherHub" device + station-type sensor) stays for the
rename round, as agreed.
314 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The health model only knew "wu"/"wslink", so with an Ecowitt setup the
active_protocol / integration_status fell back to "PWS/WU" even while Ecowitt data
was flowing.
- Replace _protocol_name() with _configured_protocol() which returns
wu / wslink / ecowitt (legacy endpoint takes precedence; ecowitt-only -> ecowitt).
- _refresh_summary: treat "ecowitt" as a real accepted protocol (active_protocol and
online_<proto> now track it); the WU-vs-WSLink mismatch -> degraded check is scoped
to the legacy pair so coexisting Ecowitt is never falsely degraded.
- Add the "ecowitt" / "online_ecowitt" entity states to strings/en/cs.
310 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
extra_state_attributes (readable by any HA user). public_health_snapshot()
strips internal network details (source IP, internal URLs, raw add-on status);
full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).
i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.
Tests: 300 passing, 100% coverage maintained; basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
- Add detailed architecture overview in __init__.py
- Introduce shared runtime keys in data.py to avoid key conflicts
- Implement dual route dispatcher for webhook endpoint selection
- Enhance sensor platform for dynamic sensor addition without reloads
- Rename battery level "unknown" to "drained" with updated icons
- Improve utils.py with centralized helpers for remapping and discovery
- Update translations and strings for consistency
Adds translations for the battery state of the outside sensor to both the English and Czech language files.
This change provides more descriptive and user-friendly information about the battery status.
Fixes#62
Fixes rainfall unit inconsistency
Updates daily rain sensor to use consistent measurement units and corrects device class and suggested unit.
Fixes#62
Adds database path constant and data migration function
Defines DATABASE_PATH constant for database file location
Introduces migrate_data function to update unit of measurement in long statistics.
Adds sensor migration feature
Introduces a migration step for sensor statistics
Updates schema and translations to support migration
Fixes data migration from mm/d to mm
Refactoring webhook switching.
Added routing management to automaticly update coordinator to avoid restarting HA on configuration change or on new sensor discovery.
- A new constant `WIND_AZIMUT` is added to allow creating a wind direction sensor that returns a text value from `UnitOfDir` instead of just a numeric degree value.
- The wind direction sensor entity now optionally creates both a numeric wind direction sensor using `WIND_DIR` and a text-based azimuth sensor using `WIND_AZIMUT`. If the numeric one is enabled, the text one will also be added.
So in summary, these changes improve the usability of wind data by adding a more human-readable text version alongside the existing numeric version.