Commit Graph

30 Commits (6248ce93d7a628bc2b5565d4ed530e611e471d31)

Author SHA1 Message Date
Guðni Már Gilbert 6248ce93d7 Update CMake integration for Catch v3.1.0 2022-10-16 20:43:50 +00:00
D.R.racer 4964e9a781 Fixup unit tests due to new homing behavior 2022-08-02 07:16:54 +02:00
D.R.racer 3c3e625f39 Unit test ErrDisengageIdler: make sure it never sets error while disengaging 2022-07-20 16:23:43 +02:00
D.R.racer d80a58cfdb Fix unit tests 2022-06-20 17:03:40 +02:00
D.R.racer 2874dd3bc9 Make sure the selector never moves if FINDA is pressed
It looks we have some kind of leak when filament sensor state is not completely coherent with FINDA state.
This is yet to be discovered and fixed with some unit tests.
2022-06-20 14:20:31 +02:00
D.R.racer b685ec4aff Fix waiting for homing of Selector after UnloadFilament 2022-02-17 08:21:15 +01:00
D.R.racer c95c6677b1 Add more unit tests for homing + fix the homing
It is a carpet-bombing-commit again, but solving the problem correctly required such an approach.
2022-02-17 08:21:15 +01:00
D.R.racer 4d9d310f00 Fix unit tests 2022-02-17 08:21:15 +01:00
D.R.racer f9addb0d7a WIP: homing on both ends of axes
The principle has been implemented, but the TMC is not providing
the right data for some reason - homing doesn't work at all right now.

Also, after solving the physical homing, unit tests must be updated.
2022-02-17 08:21:15 +01:00
D.R.racer c5e5f57100 Rename mp (modules::pulley) namespace to mpu
clashed with the already used `modules::protocol` (mp)
2022-02-17 08:21:15 +01:00
D.R.racer b36e6b99a1 Add Pulley as a Movable module
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
2022-02-17 08:21:15 +01:00
D.R.racer ea8dd7e365 Unload now rechecks the position of filament after recovery
This solves a number of issues - if FINDA or FSensor failed,
the unload was never "complete" - filament was stuck in the selector
blocking it from normal operation.

Now, after all errors have been resolved, filament is explicitly FED
into FINDA and then RETRACTED to Pulley.
2022-01-19 17:08:35 +01:00
D.R.racer 6973dbff13 Introduce intelligent homing if Idler and Selector
Both movable components now perform homing sequences transparently
whenever the logic layer invalidates the homingValid flag.
That reflects the fact, that the user may have moved the Idler or Selector
while trying to resolve a HW issue with un/loading filament.

Basic rules:
- Idler gets rehomed immediately and then moves into the target slot position
- Selector rehomes once it is possible - i.e. when filament load state
  is AtPulley - then it immediately and spontanneously executes the homing
  sequence and then returns to the desired state

Motivation:
- resolve startup issues (EEPROM says we have filament, but FINDA is not triggered)
- resolve accidental moves of Idler and/or Selector while
  digging out stuck filament from the unit
2021-11-25 13:04:22 +01:00
D.R.racer ffd8924d8c Fix start MMU with filament blocking the selector 2021-11-03 10:37:51 +01:00
D.R.racer 9438253106 Avoid trying to unload filament when not loaded
however, it looks like the EEPROM is not updated correctly, needs more testing
2021-10-21 15:16:29 +02:00
D.R.racer ee247246ee Fix unit tests
- fix homing procedure for Idler and Selector
  (homing now ends with a move to the Parking position)
- fix unit tests' startup conditions with regard to necessary
  homing of Idler and Selector

TODO: still test_cut_filament fails for minor reasons
2021-10-21 07:55:41 +02:00
D.R.racer c26cc30185 Add finer filament loaded states and improve unit tests
We need to know better where the filament is, a simple "filament loaded true/false"
does not correspond to the reality.
2021-10-12 18:11:05 +02:00
3d-gussner 382a2c8dc0 Fix unit test: feed_to_finda 2021-08-31 06:59:29 +02:00
D.R.racer 2f5dff6c5b Introduce short namespace aliases
especially for modules
2021-08-04 11:03:56 +02:00
D.R.racer b484eeacb6 Start using config.h
Added some constexpr vars for buttons, finda, fsensor and
applied them in the FW and unit tests accordingly.
2021-07-05 18:07:54 +02:00
D.R.racer ffae941a28 Fix unit tests of load/unload filament 2021-06-30 07:39:31 +02:00
D.R.racer 46a40f7488 Extend Unload filament unit tests
+ now error states are covered as well
+ greatly cleaned-up code
2021-06-30 07:39:31 +02:00
D.R.racer ce20f0b001 Greatly improve unload filament unit test
+ relevant changes for other unit tests -> prepare for improving
of the other unit tests as well
2021-06-30 07:39:31 +02:00
D.R.racer ede475c5a6 Introduce Timebase module, refactor timing code + unit tests 2021-06-21 10:22:17 +02:00
D.R.racer d9b368bb92 Verify+fix second Feed to FINDA's unit test 2021-06-21 10:22:17 +02:00
D.R.racer 85910497f7 Unify buttons' API with other modules
- accepts millis() instead of doing the timing internally (which has
been a temporary solution just for the tests until now)
2021-06-21 10:22:17 +02:00
D.R.racer 3cb3cebed9 Add forced reinit of all automata for the unit tests
+ added a few constexpr to constructors on the way
2021-06-21 10:22:17 +02:00
D.R.racer b8f6bc9a4e Tune Feed to FINDA state machine and its unit test
so that it works as expected

Still, there is a task of resetting all of the state machines just for
the next unit test to be run.
2021-06-21 10:22:17 +02:00
D.R.racer f0a042c1b6 Add unit tests for Feed to FINDA state machine
+ improve infrastructure
2021-06-21 10:22:17 +02:00
D.R.racer 925201d77a Basic unit test structure for the logic layer
It compiles the Cut Filament unit test with all the necessary components.
Still, the unit test does nothing.
2021-06-21 10:22:17 +02:00