The reasons for this change are:
- NoCommand is used during the lifetime of the firmware as a fallback in case an unknown command is received (simplifies command handling code). It must remain not doing anything.
- StartUp became a complex infrastructure which needs to "live" until an error is fixed (if any). That requires a "standard" StateInner() function which waits for the user to resolve the error.
Unit tests renamed as well.
Intended for scenarios when FINDA used to be OFF but accidentally became ON without a reason.
The user is obliged to inspect FINDA and tune its switching.
If FSENSOR_DIDNT_SWITCH_ON was caused by misaligned Idler, rehoming it may fix the issue when auto retrying -> no user intervention.
So first invalidate homing flags as the user may have moved the Idler or Selector accidentally.
Beware: we may run into issues when FINDA or FSensor do not work correctly. Selector may rely on the presumed filament position and actually cut it accidentally when trying to rehome.
It is yet to be seen if something like this can actually happen.
MMU-191
If QUEUE_FULL error happened, it would be overwritten as INTERNAL
and incorrectly display FW_RUNTIME_ERROR on MK3S.
The fix is to add handling for ERRInternal in every StepInner() and forward the error
to higher application layer
- rename stall*guard to StallGuard (match name with the vendor)
- separate TMC2130 module from EEPROM (they do not need to know about each other at all)
- separate SGTHRS settings from motion - moved to globals like all other "global" parameters
- improved EEPROM storage for SGTHRS
This is to solve a potential problem while feeding to printer's drive gears - while disengaging the Idler, the Pulley was still rotating to avoid grinding the filament (printer is pulling it).
Other filaments could have moved a bit when the Idler's bearings ran over them while the Pulley was still rotating slowly -> the filament could have been moved into the Selector's path causing trouble (especially when not used in the print).
Therefore, the Idler disengages partially now - moves into an intermediate position between the slots.
Then, the Pulley is completely stopped and after that the Idler does a full disengage like before.
It looks like we don't have to reset the whole ToolChange state machine when resolving an error with the middle button (Retry) - but jump straight into the feeding phase.
The reasons are multiple:
- If an error happens during the unload phase, it is handled separately in the UnloadFilament state machine
- If an error happens during the feeding phase, the unload has been already successfully completed.
And when restarted from the very beginning, the ToolChange does the last retract sequence from the UnloadFilament phase
-> that is not healthy, because the filament gets pushed away from the Pulley and causes another error.
Sets the UI module into a mode when the printer is in charge of processing the buttons (from all sources).
That means the MMU will detect its buttons but it will not react upon them.
This mode is important for error recovery when the printer needs to do some stuff before the MMU (like preheating the nozzle).
If the MMU receives a command LoadFilament with a slot number SL we reject
the command to avoid moving the selector (effectively cutting the piece of filament present in FINDA).
That includes the scenario when the selector is standing at the very same slot SL, because the filament could be held by the printer (i.e. loaded in the nozzle).
There is one special case though - same slot AND filament load state == InSelector (it MUST NOT be anywhere farther)
It turned out FINDA needs running timer to perform BlockingInit() correctly.
Therefore setup() was split into setup() (no IRQ) and setup2() (IRQ enabled).
Then, finally, the check for FINDA state became reliable upon start of the FW.
Originally, only FeedingToBondtech was reported to the printer.
With PR#173 we have this operation separated into a fast and a slow stage (for MK3S with the chimney).
It looks like the printer could benefit from knowing if the MMU is still pushing fast
or when it entered the slow stage (to prevent ramming hard the Bondtech gears)
Along with this new state being reported, we also introduce a new ErrorCode::FSENSOR_TOO_EARLY
which basically means that the fsensor triggered in the fast feeding stage.
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
- circular buffer can return its count of elements (even though a better solution may be implemeted later)
- stub_motion can handle multiple planned moves
- improved load/unload filament tests
This PR brings the option to move the selector directly using
buttons of the MMU - obviously while the MMU is idle and no
filament is stuck in the selector.
Left/Right buttons move the selector Left/Right.
Middle button performs a LoadFilament (into the MMU) on the active slot.
With this PR a change of LoadFilament behavior is also introduced.
Now, LoadFilament spins the Pulley for infinite time while waiting
for either FINDA trigger and/or a button pressed.