Commit Graph

914 Commits (b00ac883c4ee7e1087bf0c2234444ced0e426127)

Author SHA1 Message Date
D.R.racer 4fa352b4fa Change minimum unit tests to reflect new version nr 2023-07-20 10:28:58 +02:00
D.R.racer 77691e93fb Tag 2.1.9 as 3.0.0
Getting ready for the release
2023-07-20 10:28:58 +02:00
D.R.racer 554caa24fa Update build server config 2023-07-13 16:24:06 +02:00
Guðni Már Gilbert 1633d9af9b Optimise CircularIndex count
No change in memory
2023-06-12 07:42:25 +02:00
Guðni Már Gilbert edec4708b5 MMU-239 Add unit test for FINDA flickering when ejecting filament
The test case test the error recovery on all MMU slots.
2023-06-12 07:39:25 +02:00
Guðni Már Gilbert 4d3067213f MMU-239 Add unit test for ejecting slots 0-4
This test ejects slots 0 to 4 and goes through the state machine
without creating any errors like FINDA_FLICKERS.

It also verifies the selector parking position is correct for each
ejected filament slot.
2023-06-12 07:39:25 +02:00
Guðni Már Gilbert 48ea52bd47 Minor header cleanup 2023-06-12 07:39:25 +02:00
Guðni Már Gilbert ddc962067c Fix missing ErrorCode::RUNNING
This is needed in case we are recovering
from FINDA_FLICKERS
2023-06-12 07:39:25 +02:00
Guðni Már Gilbert 9842375450 Improve homing behavior more
Split the wait for HomingValid and the event where we wait
for the Selector/Idler status to go 'Ready' into separate functions
2023-06-12 07:04:51 +02:00
Guðni Már Gilbert bfc953f52d Add more strings to error output in unit tests 2023-06-12 07:04:51 +02:00
Guðni Már Gilbert eb52475819 Improve selector homing behavior in unit tests
Waiting for the selector to return to the parked position after homing
is not enforced by the firmware and should therefore not be enforced by
the unit tests. There are some few exceptions to this, and for those
situations I added a parameter to SimulateSelectorHoming() called
waitForParkedPosition to explicitly wait for the selector to return to
the parked position if set to true. This is very useful when setting up
test cases in general and also allows us to control the behavior in each
test.
2023-06-12 07:04:51 +02:00
Guðni Már Gilbert 372045c38c Update cut filament unit test 2023-06-12 07:04:51 +02:00
Guðni Már Gilbert 20a2ee7d56 Fix false FINDA_FLICKERS on Toolchange retry
Delay reporting the cut command finished until the selector has returned
back to the cutting slot. This was done by adding ProgressCode::Homing
to the Cut Filament state machine. ProgressCode::ReturningSelector is
then used to wait for the selector to return back to the cut slot after
homing becomes valid again. Only then is the cut operation reported
finished and a new command can be processed e.g. Toolchange.

Change in memory:
Flash: +16 bytes
SRAM: 0 bytes
2023-06-12 07:04:51 +02:00
Guðni Már Gilbert 8c873c8a53 cleanup: unit tests: Remove unused Catch namespace 2023-06-04 14:06:03 +00:00
3d-gussner 6532a435d2 Update doxygen pulley values 2023-05-05 10:40:51 +02:00
3d-gussner 342b95bb18 Set pulley to 95mm/s for load and unload
Set pulley to 230mA current to prevent grinding
2023-05-04 11:01:11 +02:00
Guðni Már Gilbert 4a315c920a Remove redundant call to SetPairButOffOthers
retract.Reset takes care of setting the green LED to blink.
Might as well turn of the red LED during reset just in case.

Change in memory:
Flash: -30 bytes
SRAM: 0 bytes
2023-05-04 07:51:45 +02:00
Guðni Már Gilbert c096725674 modules: leds: Implement SetAllOff()
A helper function which turns of all LEDs
reduces code size :)

Change in memory:
Flash: -64 bytes
SRAM: 0 bytes
2023-05-02 07:32:27 +02:00
Guðni Már Gilbert c6c23e2c06 logic: eject_filament: reset LED state on OK event
Fix a minor issue where once the FILAMENT_EJECTED error screen
is shown on the MK3S+, the LEDs will stay blinking red even after
the user has removed the filament and clicked "Done".

My proposal is to turn the LED off.

Steps to reproduce:
1. Boot up printer and MMU in a clean state
2. MK3S+: on the LCD click "Load to Nozzle"
3. Once the loading is done, click "Unload filament"
4. Once unloading is done, click "Eject filament"
5. FILAMENT_EJECTED MMU error screen appears on the printer's UI
6. Remove the filament and select "Done".
* Expected behavior: Blinking red LED turns off (or goes green).
* Actual behavior: LED continous to blink red with no error screen.

Change in memory:
Flash: +16 bytes
SRAM: 0 bytes
2023-05-02 07:32:27 +02:00
Guðni Már Gilbert 605fa412ef Fix compiler error on GCC 12
static_assert(sizeof(ChopConfU::S) == 4) would return 5 == 4
static_assert(sizeof(ChopConfU) == 4); would return 8 == 4

using uint32_t on all types instead of uint8_t fixes the issue

No change in memory
2023-05-02 07:16:50 +02:00
D.R.racer 113f71330e Disable register 0x21 2023-03-14 18:14:26 +01:00
D.R.racer f07e206398 Hold/Resume Idler+Selector even after their homing errors
MMU-222
2023-03-14 18:14:02 +01:00
D.R.racer bafad408b7 Hold Idler and Selector even in logic::StartUp error handling
StartUp doesn't share the common ErrDisengageIdler code so the hold/resume must be used explicitly.
2023-03-14 18:08:10 +01:00
D.R.racer c4e23b687d Clean-up TMC SG trs setting in COOLCONF register 2023-03-14 17:58:11 +01:00
D.R.racer f0a633b4b6 Ignore Idler's SG signal from TMC when rolling over filaments 2023-03-14 17:58:11 +01:00
D.R.racer d9c4d61fec Optimize LED writes 2023-03-14 17:58:11 +01:00
D.R.racer b97b7561c6 Ignoring the diag pin (stallguard) completely in specified range
This seems to greatly improve overall homing reliability of Idler on MMUs which couldn't home with inserted filaments at all.
The only downside is the fact, that we may actually "home" a blocked Idler correctly.
2023-03-14 17:58:11 +01:00
D.R.racer 95915cb080 Prototype adaptive Idler homing sg_thrs
Needs to be tweaked further to make it a production code.
But my primary concern now is the fact that it doesn't seem to help too much while homing over the too-tightened Idler cover.
2023-03-14 17:58:11 +01:00
D.R.racer 59bbe0274a Reallocate MCU_UNDERVOLTAGE_VCC error code value 2023-03-08 15:14:36 +01:00
D.R.racer 98ef2368a0 Rename CurrentVCC->CurrentBandgapVoltage
and tune surrounding comments
2023-03-08 15:14:36 +01:00
D.R.racer 314233b37f Add runtime VCC measurement as register
- extract logic of undervoltage handling into main.cpp
- fix unit tests
- bump version to 2.1.9 (new register)
2023-03-08 15:14:36 +01:00
Alex Voinea 23a9978980 VCC undervoltage check module 2023-03-08 15:14:36 +01:00
Alex Voinea 372c65ef1d Fix ReadADC channel selection 2023-03-08 15:14:36 +01:00
D.R.racer 8b55b25028 Allow cutting current >31
Needs reinitialization of the axis (Selector) because the TMC driver needs to set another register to double the current level.
2023-03-07 21:07:52 +01:00
D.R.racer 9b43b61939 Idler+Selector homing speeds: writeable registers 2023-03-02 19:54:50 +01:00
D.R.racer b573fb1da3 Fix indentation 2023-03-02 12:20:06 +01:00
D.R.racer d2a2014b89 Cleanup HoldOn-Resume code in movables 2023-03-02 12:20:06 +01:00
D.R.racer e089a84f48 Turn off Idler and Selector motors before entering an error screen
That should prevent overheating and allow servicing during and error state.

MMU-216
2023-03-02 12:20:06 +01:00
D.R.racer ea41fd6b83 Update unit tests 2023-03-02 12:20:06 +01:00
D.R.racer d75119c8d6 Suspend all moves of Idler and Selector when entering an Error screen 2023-03-02 12:20:06 +01:00
D.R.racer 436ebcbeee Add HW EEPROM reset
Now the whole functionality takes +196B

As noted by @leptun, we cannot reliably check for >1 buttons pressed at once.
Since the left button is the least used, let's use it for invoking the HW EEPROM clear upon MMU start.
2023-02-25 17:59:35 +01:00
D.R.racer e2ee6f6ff1 Add X42 as EEPROM reset command + handling + visualization
MMU-193
2023-02-25 17:59:35 +01:00
D.R.racer 7e2375deee Introduce TMC2130 currents doxy group
and clean-up doxygen warnings a bit
2023-02-17 15:50:20 +01:00
Alex Voinea 9fce324bff Increase Idler SG_THRS to 7 2023-02-15 08:09:16 +01:00
D.R.racer ebdcc5a7e3 Increase version to 2.1.7
... due to removed left and right button handling in error states.
2023-02-10 14:39:45 +01:00
D.R.racer 009c692138 Remove related unit tests 2023-02-10 14:39:45 +01:00
D.R.racer 75a0ebaf0e Remove handling of left+right buttons in error states
Based on long-term test experience - saves some code + prevents the user from entering hard-to-understand states.
Only Retry remains as the one and only way of recovering from errors.
2023-02-10 14:39:45 +01:00
D.R.racer 2b5a129c7d Add new error codes 2022-12-30 14:44:12 +01:00
D.R.racer db2125e67a Bump version to 2.1.6
new features coming:
- Cut Filament
- Eject Filament
- probably also settable motor currents
2022-12-30 14:44:12 +01:00
D.R.racer 414ee1e0ca Finish EjectFilament operation 2022-12-30 14:44:12 +01:00