If the MMU receives a command LoadFilament with a slot number SL we reject
the command to avoid moving the selector (effectively cutting the piece of filament present in FINDA).
That includes the scenario when the selector is standing at the very same slot SL, because the filament could be held by the printer (i.e. loaded in the nozzle).
There is one special case though - same slot AND filament load state == InSelector (it MUST NOT be anywhere farther)
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
- circular buffer can return its count of elements (even though a better solution may be implemeted later)
- stub_motion can handle multiple planned moves
- improved load/unload filament tests
This PR brings the option to move the selector directly using
buttons of the MMU - obviously while the MMU is idle and no
filament is stuck in the selector.
Left/Right buttons move the selector Left/Right.
Middle button performs a LoadFilament (into the MMU) on the active slot.
With this PR a change of LoadFilament behavior is also introduced.
Now, LoadFilament spins the Pulley for infinite time while waiting
for either FINDA trigger and/or a button pressed.
Load filament performs feed to FINDA and retract:
- engage idler
- feed normal to FINDA with config::feedToFinda distance until FINDA triggers
- retract normal and as soon FINDA un-triggers move back to PTFE config::cuttingEdgeToFindaMidpoint
- disengage the idler
That implied introducing another substate machine - RetractFromFinda, which does the opposite
of FeedToFinda while also checking for the FINDA switching off while retracting filament.
Still, ToolChange and CutFilament need fixing with this change