Coverage went from 54 of 107 upload parameters to all 107, adding roughly 34
entities. New families: Type5 lightning, Type6 water leak (CH1-7), Type8
particulate matter, Type10 CO2 and Type11 CO, plus the parameters missing from
existing families - absolute pressure, feels-like temperature, the 10-minute
average wind speed, and the per-channel probe type.
Device classes follow Home Assistant's own list (PM25, PM10, AQI, CO2, CO,
DISTANCE, ATMOSPHERIC_PRESSURE, WIND_SPEED, and binary MOISTURE for leaks), so
the readings work with statistics and unit conversion without template helpers.
Batteries were the trap. The API annotates two incompatible conventions -
"(Normal=1, Low battery=0)" and "(0~5) remark: 5 is full" - and mixing them up is
silent, because a level battery read as a flag reports "not low" for every level
above empty. Eight new binary batteries (t5lsbat, t6c1-7bat) and three new level
batteries (t8bat, t10bat, t11bat) are classified from the document, and
tests/test_wslink_api_coverage.py pins each one to the wording it came from.
Water leak and battery use opposite conventions in the same family (leak 1 means
wet, battery 0 means low), so `on_value` moved into the description and one
entity class now serves both instead of two that differ by a comparison.
`t1cn` was in the API but wired to nothing, so a disconnected outdoor probe kept
publishing its last readings. Gating it required fixing the gate first: an absent
connection flag was treated as "disconnected", which would have blanked
temperature, wind and rain outright on any firmware that omits `t1cn`. Absence is
now treated as no information, and only an explicit non-1 drops the readings.
The probe type (`t234cXtp`) decides whether a channel's humidity reading is air
humidity or soil moisture, which are different device classes. It is resolved
once, when the entity is created, because Home Assistant records the device class
in the entity registry; swapping the physical probe means reinstalling.
Two parameters are handled with a documented caveat: `inbat` is the only battery
whose scale the API does not state and stays a 0/1 flag, and `t5lst` has no unit
(the vendor example uses 9999) so it is read as minutes with 9999 meaning
"nothing recorded".
Also replaces the now-stale TODO block in const.py - it listed exactly these
sensors as unimplemented - and documents the complete coverage in the README.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.
The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.
No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.
Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- S8: received_data now rejects empty configured credentials (IncorrectDataError)
and present-but-empty incoming credentials (HTTPUnauthorized) instead of relying
solely on the config flow. Credential validation extracted into
_validate_credentials() (also resolves the C901 complexity warning and unifies
the WU/WSLink branches).
- S6: cap auto-created native Ecowitt entities (MAX_NATIVE_ECOWITT_SENSORS) to bound
entity-registry growth from a fabricated multi-key payload.
- S5: store only the exception class name in Windy/Pocasi last_error (surfaced via
entity attributes; str(ex) could embed the request URL).
- S7: verified safe - the native-sensor INFO log is parametrized (%s), so no
format-string injection; left as-is.
308 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
concurrent webhooks can no longer both pass the rate-limit check and double-send
(which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
config-entry reload (update_listener now skips reload for live-read flags
SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().
Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The /station/health route is registered directly on the aiohttp router, so HA's
auth middleware only flags requests without blocking them - the endpoint was
reachable unauthenticated and returned the full health snapshot.
- health_status now requires HA authentication (bearer token or signed request)
via KEY_AUTHENTICATED and returns 401 otherwise.
- Mask the Ecowitt webhook id (the endpoint's only credential) in last_ingress
paths via _sanitize_path, so it never enters the snapshot exposed by the health
endpoint or the diagnostics download.
- Redact ECOWITT_WEBHOOK_ID in diagnostics.
- Compare the Ecowitt webhook id in constant time (hmac.compare_digest), matching
the WU/WSLink credential checks.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Pass config_entry explicitly to super().__init__() in both
WeatherDataUpdateCoordinator and HealthCoordinator instead of relying on the
implicit ContextVar (deprecated, breaks in HA 2026.8 for core and was breaking
async_config_entry_first_refresh outside the setup context).
Also resolve each discovered sensor's display name once in received_data
(the previous comprehension awaited translations() twice per key).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors