- Reject blank or whitespace-only PWS credentials in both the config flow and
the options flow. INVALID_CREDENTIALS only held placeholder strings, so an
empty API ID or key passed validation, the entry was created, and
_validate_credentials then rejected every incoming packet.
- Fall back to "UNKNOWN" host/port when get_url raises NoURLAvailableError.
The values are shown as Ecowitt setup instructions only, so an unresolvable
Home Assistant URL must not make the step unreachable.
- Catch TimeoutError alongside ClientError in the Windy and Pocasi push paths.
A timeout is not a ClientError and used to escape into the webhook handler,
answering the station with HTTP 500 even though the measured data was
already stored.
- Add regression tests for all three and pin that 0-5 battery descriptions
really reach the WSLink sensor platform.
Forwarders (Windy / Pocasi):
- `enabled` becomes a property reading the option live. Toggling it does not
reload the entry, so the cached copy left the diagnostics sensor reporting a
stale value indefinitely for a disabled forwarder.
- Reject empty credentials explicitly: an empty string is still a `str`, so
`checked` alone let an unconfigured forwarder send a request that could only
ever be refused.
- Use `persistent_notification.async_create` instead of the sync variant.
- Use WINDY_MAX_RETRIES consistently; add POCASI_CZ_MAX_RETRIES.
Utils:
- `voc_level_to_text` / `battery_5step_to_pct` go through `to_int` like every
other value_fn. A bare `int()` raised on a garbage payload value, which
`WeatherSensor.native_value` then logged with a full traceback on every push.
Out-of-range battery steps are clamped to a valid percentage.
- Simplify `check_disabled` (drop the redundant camelCase flag).
Config flow:
- `retain_data` re-reads SENSORS_TO_LOAD at submit time. Auto-discovery appends
to it from the webhook handler, so writing back the snapshot taken when the
step opened silently rolled back any sensor discovered meanwhile.
Coordinator:
- Drop the per-push staleness recalculation; the hourly timer already covers it.
Ecowitt:
- Tolerate aioecowitt moving/renaming the internal SENSOR_MAP rather than
failing the whole module import; unit-variant dedup degrades instead.
Translations:
- Battery state key `unknown` -> `drained`: the entity emits UnitOfBat.UNKNOWN,
whose value is "drained", so the old key never matched and the raw state
leaked into the UI. cs.json was already correct.
- Remove the dead `migration` step; `async_step_migration` does not exist.
Also: remove verified-dead constants/helpers and fix ~30 docstring typos.
Add POCASI_CZ_MAX_RETRIES and map HTTP status codes to explicit send
outcomes. Use the status (not the empty body) to classify sends as
"ok", "auth_error", or "unexpected_response". Introduce _disable_pocasi
to persistently turn off resending and record errors. Count unexpected
responses and disable resends after the retry limit; adjust client-error
handling to reuse the same disable logic. Update tests and config flow
expectations to match the new behavior.
Extract WSLink add-on probe and treat expected network errors and
NoURLAvailableError as "offline" instead of raising. Log unexpected
errors and avoid raising ConfigEntryNotReady from diagnostics probes.
Add tests for probe robustness, add additional sensitive purge keys,
and fix config_flow host fallback handling.
All entities (weather, battery, health, native Ecowitt) now report through a
single device under the existing {(DOMAIN,)} identifier, removing the separate
"Ecowitt {model}" device that appeared whenever Ecowitt was enabled. This
collapses the previous two-device layout (and the duplicate/untranslated native
Ecowitt sensors living on the second device) into one.
The device model reflects the running station type via _station_model():
"Ecowitt <model>" when Ecowitt is active (model learned from the payload's
`model` field and stored on runtime_data.ecowitt_model), else "WSLink", else
"PWS". Device identity is centralised in data.build_device_info() and reused by
every platform.
No device-registry migration is required: the identifier is unchanged; only the
model/grouping change. Full device unification under a renamed hub is deferred
to the rename round.
Tests: device-info assertions updated to the shared device across the entity
suites; new _station_model/build_device_info branch coverage in test_data.py;
received_ecowitt now asserts the learned model. 320 passed, 100% coverage.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Two long-standing rough edges with Ecowitt running alongside the SWS device:
- Dedup (#1): aioecowitt emits both metric and imperial sensors per quantity
(tempc/tempf, rainratemm/rainratein, ...). Only the imperial twin is mapped to the
SWS sensors, so the metric twin (and other unmapped extras) showed up as duplicate
native entities. _on_new_sensor now skips a key whose unit-variant twin is already
mapped or already created (twin groups derived from aioecowitt's SENSOR_MAP). HA
converts units via device_class, so a single variant suffices.
- Translation (#2): native sensors used the raw English aioecowitt name. Common
single-instance families (rain rate / hourly / event / 24h / weekly / monthly /
yearly / total rain, absolute pressure, feels-like, indoor dew point, CO2) now use
curated translation_keys (added to strings/en/cs); long-tail / multi-channel
sensors keep the English name fallback.
- Also add the imperial RAIN_RATE_INCHES / RAIN_COUNT_INCHES to STYPE_TO_HA so those
native rain sensors get a device class and unit.
Device unification (one "WeatherHub" device + station-type sensor) stays for the
rename round, as agreed.
314 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The health model only knew "wu"/"wslink", so with an Ecowitt setup the
active_protocol / integration_status fell back to "PWS/WU" even while Ecowitt data
was flowing.
- Replace _protocol_name() with _configured_protocol() which returns
wu / wslink / ecowitt (legacy endpoint takes precedence; ecowitt-only -> ecowitt).
- _refresh_summary: treat "ecowitt" as a real accepted protocol (active_protocol and
online_<proto> now track it); the WU-vs-WSLink mismatch -> degraded check is scoped
to the legacy pair so coexisting Ecowitt is never falsely degraded.
- Add the "ecowitt" / "online_ecowitt" entity states to strings/en/cs.
310 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
API_KEY, WINDY_STATION_PWD and POCASI_CZ_API_KEY now use a password TextSelector so
the values are masked in the UI. Field keys are unchanged, so stored options and the
flow contract are unaffected.
308 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Every entity translation_key used in code now resolves in cs.json (Czech users with
channels 5-8 or the deprecated enum battery sensors no longer see raw keys).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- manifest: add single_config_entry, integration_type "device", loggers
["aioecowitt"]; drop empty homekit/ssdp/zeroconf placeholders.
- Q10: raise ConfigEntryNotReady (not PlatformNotReady) when route registration
fails in async_setup_entry; drop the now-unused import.
- Q11: delete the ~105-line commented-out sqlite3 statistics-migration block in
utils.py (would have been blocking I/O in the event loop) and its dead import.
Deferred (with reason): quality_scale (needs a rule audit + quality_scale.yaml),
device-identifier 2-tuple and suggested_entity_id (entity-naming/identity changes,
to land with the planned integration rename), CoordinatorEntity generics in
sensor.py (would introduce a circular import - intentionally untyped).
Note: the health-probe protocol gate was reverted - the proxy add-on can front
WU/WSLink/Ecowitt, so polling must stay unconditional.
308 passing, 100% coverage; ruff clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- S8: received_data now rejects empty configured credentials (IncorrectDataError)
and present-but-empty incoming credentials (HTTPUnauthorized) instead of relying
solely on the config flow. Credential validation extracted into
_validate_credentials() (also resolves the C901 complexity warning and unifies
the WU/WSLink branches).
- S6: cap auto-created native Ecowitt entities (MAX_NATIVE_ECOWITT_SENSORS) to bound
entity-registry growth from a fabricated multi-key payload.
- S5: store only the exception class name in Windy/Pocasi last_error (surfaced via
entity attributes; str(ex) could embed the request URL).
- S7: verified safe - the native-sensor INFO log is parametrized (%s), so no
format-string injection; left as-is.
308 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- C1: received_data / received_ecowitt_data return 503 (not 500) when the entry is
mid-reload (runtime_data gone); add_new_sensors / add_new_binary_sensors are
defensive no-ops in that window too.
- C2/C3: Windy and Pocasi reserve their next send window *before* the await, so
concurrent webhooks can no longer both pass the rate-limit check and double-send
(which could falsely trip the auto-disable threshold).
- C5: EcowittBridge.set_add_entities flushes unmapped sensors parsed before the
platform was ready (aioecowitt fires new_sensor_cb only once per key).
- C6: a forwarder auto-disabling itself from the hot path no longer forces a full
config-entry reload (update_listener now skips reload for live-read flags
SENSORS_TO_LOAD / WINDY_ENABLED / POCASI_CZ_ENABLED).
- C7: to_int accepts decimal-formatted integers ("180.0").
- C8: forwarders use dt_util.utcnow() (UTC-aware) instead of naive datetime.now().
Tests updated; 305 passing, 100% coverage; ruff + basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Security (from the deep audit):
- S1: health "integration_health" sensor no longer dumps the full snapshot in
extra_state_attributes (readable by any HA user). public_health_snapshot()
strips internal network details (source IP, internal URLs, raw add-on status);
full data stays on the authenticated endpoint and admin-only diagnostics.
- S2: anonymize() now masks the Ecowitt passkey/PASSKEY.
- S3: Windy station id masked before logging the dataset.
- S4: diagnostics redacts internal network fields (source IP, URLs, raw_status).
i18n (Q1/Q2):
- Sync strings.json + en.json with the actual flow: add wslink_port_setup step,
the ecowitt/pocasi/wslink_port_setup menu entries, the pocasi_* and
windy_key_required error keys, the stale_sensors_detected issue; fix wrong data
keys (WSLINK->wslink + legacy_enabled, POCASI_CZ_SEND_INTERVAL->POCASI_SEND_INTERVAL,
pocasi_enabled_checkbox->pocasi_enabled_chcekbox); translate the English ecowitt
options step (was Czech); de-duplicate the legacy-battery issue description.
- Q2: rename wbgt_index -> wbgt_temp to match the entity translation_key.
- cs.json: add windy_key_required and fix the pocasi data/data_description keys.
Tests: 300 passing, 100% coverage maintained; basedpyright clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The /station/health route is registered directly on the aiohttp router, so HA's
auth middleware only flags requests without blocking them - the endpoint was
reachable unauthenticated and returned the full health snapshot.
- health_status now requires HA authentication (bearer token or signed request)
via KEY_AUTHENTICATED and returns 401 otherwise.
- Mask the Ecowitt webhook id (the endpoint's only credential) in last_ingress
paths via _sanitize_path, so it never enters the snapshot exposed by the health
endpoint or the diagnostics download.
- Redact ECOWITT_WEBHOOK_ID in diagnostics.
- Compare the Ecowitt webhook id in constant time (hmac.compare_digest), matching
the WU/WSLink credential checks.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The azimut value_from_data_fn now passes dir.get(WIND_DIR) (typed Any | None),
which tripped basedpyright reportArgumentType against the float-only signature.
The body already coerces via to_float() and handles None, so widen the
annotation to match the real inputs (raw str payload, float, or None).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- wind_dir_to_text: treat 0/missing direction as None (calm) so a missing
wind direction no longer renders as North; azimut lambdas pass None too.
- windy: log response status (was logging an un-awaited coroutine method);
count "unexpected response" toward the disable threshold even when logging
is off.
- pocasi: disable threshold >3 -> >=3 to match Windy's 3-strike behavior.
- ecowitt: always attach device_info to native sensors, including unknown
sensor types (previously left orphaned without a device).
- const: stop remapping WSLink connection flags (t1cn/t234cXcn) into the
payload; they had no entity and leaked ghost *_connection keys into data
and persisted SENSORS_TO_LOAD. Gating uses the raw keys and is unaffected.
- config_flow: fix WSLink port fallback typo 433 -> 443; drop mutable default
argument on async_step_init.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Pass config_entry explicitly to super().__init__() in both
WeatherDataUpdateCoordinator and HealthCoordinator instead of relying on the
implicit ContextVar (deprecated, breaks in HA 2026.8 for core and was breaking
async_config_entry_first_refresh outside the setup context).
Also resolve each discovered sensor's display name once in received_data
(the previous comprehension awaited translations() twice per key).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
After a config reload a new HealthCoordinator is created, but the sticky
/station/health route kept calling the previous (stale) instance. Add
Routes.rebind_handler() and call it from async_setup_entry's reload branch
so the endpoint always serves the current coordinator.
Also make _resolve_route() tolerant of requests without match_info/route/
resource instead of raising AttributeError.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- Reuse existing `WeatherDataUpdateCoordinator` instance across reloads instead of
creating a new one; routes keep pointing to the same coordinator, so entities
stay subscribed and updates never silently drop
- `update_listener` now skips full reload when only `SENSORS_TO_LOAD` changes
(auto-discovery); avoids the "frozen UI" window caused by temporary platform unload
- Replaced direct `route._handler` mutation with a proper `Routes` dispatcher;
all aiohttp routes are registered once and an internal dispatcher decides which
handler is active — safe to switch at runtime without touching the router
- Fixed `self.config_entry` / `self.config` inconsistency in coordinator
- `BatteryBinarySensor` now carries correct `device_info` (same identifiers as
`WeatherSensor`) → single device card in UI instead of two
- Translations for binary sensors must live under `entity.binary_sensor.*`,
not `entity.sensor.*`
- Fixed all tests broken by new `register_path(hass, coordinator, coordinator_h, entry)` signature
- Updated `_RouterStub` to accept `name=` kwargs and return objects with `.method`
- Added `async post()` to `_RequestStub` stubs
- Aligned `Routes` tests with new `method:path` dispatch key format and `show_enabled()` output
- Replaced `WindyApiKeyError` with `WindyPasswordMissing` to match actual exceptions
- Updated `_FakeResponse` to use HTTP status codes instead of response text strings
- Patched `persistent_notification.create` in Windy push tests to avoid `SimpleNamespace` errors
Updated config flow's initial setup.
Ecowitt stations does not require `API_ID` and `API_KEY`, so we need to
separate Ecowitt setup from PWS/WSLink setup.
Adds the SWSRuntimeData dataclass and SWSConfigEntry type alias so
per-entry state can move from loosely-typed hass.data[DOMAIN][entry_id]
dicts to HA 2025+ typed entry.runtime_data. The legacy ENTRY_* string
keys are kept in place for now so callers can be migrated incrementally.
This commit is not final update. Just preparing for future complete refactor.
- Integrate aioecowitt to parse incoming weather station payloads and map sensors to the SWS pipeline.
- Add a new webhook endpoint at /weatherhub/{webhook_id} with support for dynamic route resolution.
- Expand battery binary sensor definitions and implement logic for dynamic entity creation.
- Bump version to 2.0.0-pre1.
- Introduce `to_int`/`to_float` helpers to safely handle None/blank payload values.
- Use the converters across weather/wslink sensor descriptions and simplify wind direction handling.
- Add low-battery binary sensor entities and definitions.
Include HTTP method in route keys and dispatch, and fix
Routes.show_enabled.
Update register_path to accept a HealthCoordinator and adjust router
stubs in tests. Update WindyPush tests to use response objects
(status/text)
and adapt related exception/notification expectations.
Introduce HealthSensorEntityDescription and a tuple of sensor
descriptions for integration status, source IP, base URL and addon
response. Instantiate one HealthDiagnosticSensor per description in
async_setup_entry. Update HealthDiagnosticSensor to accept a
description, derive unique_id from description.key and add a cached
device_info returning a SERVICE-type device. Adjust imports.
Replace manual isinstance checks and casts with py_typecheck.checked()
to validate hass and entry data and return early on errors. Simplify
add_new_sensors by unwrapping values, renaming vars, and passing the
coordinator to WeatherSensor
Use checked and checked_or to validate option and hass.data types,
remove unsafe typing.cast calls, simplify coordinator and entry_data
handling, and cache boolean option flags for Windy and Pocasí checks