# XT211 HAN Home Assistant Integration
[![hacs_badge](https://img.shields.io/badge/HACS-Custom-orange.svg)](https://github.com/hacs/integration)
![Maintained](https://img.shields.io/maintenance/yes/2026)
> **Čtení dat z elektroměru Sagemcom XT211 (ČEZ Distribuce) přes RS485-to-Ethernet adaptér bez ESP32.**
Tato integrace nahrazuje ESPHome řešení s ESP32 + RS485→TTL převodníkem. Místo toho používá průmyslový RS485-to-Ethernet adaptér (doporučen **PUSR USR-DR134**), který posílá syrová RS485 data přes TCP přímo do Home Assistantu.
---
## Jak to funguje
```
XT211 / WM-RelayBox
└── RJ12 HAN port (RS485, 9600 baud)
└── USR-DR134 (RS485 → Ethernet)
└── TCP socket (LAN)
└── Home Assistant (tato integrace)
```
Elektroměr posílá DLMS/COSEM PUSH zprávy každých **60 sekund**. Integrace udržuje persistentní TCP spojení k adaptéru a dekóduje příchozí HDLC rámce.
---
## Požadavky
- Home Assistant 2024.1+
- RS485-to-Ethernet adaptér s TCP server módem:
- **PUSR USR-DR134** (doporučeno) RS485, DIN rail, 524V
- Nebo jiný kompatibilní adaptér (USR-TCP232-410S, Waveshare, apod.)
---
## Instalace přes HACS
1. Otevři HACS → **Integrace** → tři tečky vpravo nahoře → **Vlastní repozitáře**
2. Přidej URL tohoto repozitáře, kategorie: **Integration** (https://github.com/nero150/CEZ_rele_box)
3. Najdi „XT211 HAN" a nainstaluj
4. Restartuj Home Assistant
5. **Nastavení → Zařízení a služby → Přidat integraci → XT211 HAN**
---
## Nastavení adaptéru USR-DR134
Nastavení přes webové rozhraní adaptéru (výchozí IP `192.168.0.7`):
| Parametr | Hodnota |
|----------|---------|
| Work Mode | **TCP Server** |
| Local Port | `8899` (nebo libovolný) |
| Baud Rate | `9600` |
| Data Bits | `8` |
| Stop Bits | `1` |
| Parity | `None` |
| Flow Control | `None` |
> ⚠️ Použij model **USR-DR134** (RS485), ne DR132 (RS232)!
---
## Zapojení
```
WM-RelayBox HAN port (RJ12):
Pin 3 (Data A+) → USR-DR134 terminal A+
Pin 4 (Data B-) → USR-DR134 terminal B-
Pin 6 (GND) → USR-DR134 GND (volitelné)
```
Napájení USR-DR134: 524V DC (např. z USB adaptéru přes step-up, nebo 12V zdroj).
---
## Dostupné entity (27 celkem)
### 📊 Výkon (W) okamžité hodnoty
| # | Název entity | OBIS kód |
|---|---|---|
| 5 | Power Limiter Value | `0-0:17.0.0.255` |
| 13 | Active Power Import | `1-0:1.7.0.255` |
| 14 | Active Power Import L1 | `1-0:21.7.0.255` |
| 15 | Active Power Import L2 | `1-0:41.7.0.255` |
| 16 | Active Power Import L3 | `1-0:61.7.0.255` |
| 17 | Active Power Export | `1-0:2.7.0.255` |
| 18 | Active Power Export L1 | `1-0:22.7.0.255` |
| 19 | Active Power Export L2 | `1-0:42.7.0.255` |
| 20 | Active Power Export L3 | `1-0:62.7.0.255` |
### ⚡ Energie (kWh) kumulativní
| # | Název entity | OBIS kód |
|---|---|---|
| 21 | Energy Import | `1-0:1.8.0.255` |
| 22 | Energy Import T1 | `1-0:1.8.1.255` |
| 23 | Energy Import T2 | `1-0:1.8.2.255` |
| 24 | Energy Import T3 | `1-0:1.8.3.255` |
| 25 | Energy Import T4 | `1-0:1.8.4.255` |
| 26 | Energy Export | `1-0:2.8.0.255` |
### 🔀 Binární senzory (zapnuto/vypnuto)
| # | Název entity | OBIS kód |
|---|---|---|
| 4 | Disconnector Status | `0-0:96.3.10.255` |
| 6 | Relay R1 Status | `0-1:96.3.10.255` |
| 7 | Relay R2 Status | `0-2:96.3.10.255` |
| 8 | Relay R3 Status | `0-3:96.3.10.255` |
| 9 | Relay R4 Status | `0-4:96.3.10.255` |
| 10 | Relay R5 Status | `0-5:96.3.10.255` |
| 11 | Relay R6 Status | `0-6:96.3.10.255` |
### 📋 Diagnostika (text)
| # | Název entity | OBIS kód |
|---|---|---|
| 1 | COSEM Logical Device Name | `0-0:42.0.0.255` |
| 3 | Serial Number | `0-0:96.1.0.255` |
| 12 | Current Tariff | `0-0:96.14.0.255` |
| 27 | Consumer Message | `0-0:96.13.0.255` |
> Idx 2 (`0-2:25.9.0.255` Push setup) je interní konfigurační objekt elektroměru, neobsahuje měřená data.
---
## Ladění (debug)
Přidej do `configuration.yaml`:
```yaml
logger:
default: warning
logs:
custom_components.xt211_han: debug
```
V logu uvidíš surová hex data každého HDLC rámce a dekódované OBIS hodnoty.
---
## Struktura repozitáře
```
custom_components/xt211_han/
├── __init__.py # Inicializace integrace
├── manifest.json # Metadata pro HA / HACS
├── const.py # Konstanty
├── config_flow.py # UI průvodce nastavením
├── coordinator.py # TCP listener + DataUpdateCoordinator
├── sensor.py # Senzorová platforma
├── dlms_parser.py # HDLC / DLMS / COSEM parser
├── strings.json # Texty UI
└── translations/
├── cs.json # Čeština
└── en.json # Angličtina
```
---
## Poděkování / Credits
- [Tomer27cz/xt211](https://github.com/Tomer27cz/xt211) původní ESPHome komponenta a dokumentace protokolu
- ČEZ Distribuce dokumentace OBIS kódů a RS485 rozhraní
---
## Licence
MIT