Commit Graph

27 Commits (08f777b5cbccaf5eb6bff70603d791c8472329dd)

Author SHA1 Message Date
D.R.racer 08f777b5cb Introduce FINDA_FLICKERS error code
Intended for scenarios when FINDA used to be OFF but accidentally became ON without a reason.
The user is obliged to inspect FINDA and tune its switching.
2022-11-17 07:32:38 +01:00
vintagepc 9c7701c123
Merge pull request #203 from prusa3d/vintagepc-check-hardware
Add module to check for sketchy electronics
2022-09-22 12:17:04 -04:00
D.R.racer 0fa8a3c278 Refactor original solution from @leptun
- rename stall*guard to StallGuard (match name with the vendor)
- separate TMC2130 module from EEPROM (they do not need to know about each other at all)
- separate SGTHRS settings from motion - moved to globals like all other "global" parameters
- improved EEPROM storage for SGTHRS
2022-09-22 12:16:41 +02:00
VintagePC 10fd23700b Improve implementation 2022-09-16 19:39:27 -04:00
VintagePC 973db11bec First pass/WIP 2022-09-13 08:47:27 -04:00
3d-gussner 9c751d592d Update register documentation 2022-09-09 16:57:04 +02:00
D.R.racer fbb46e5951 Distinguish fast and slow feed stage
Originally, only FeedingToBondtech was reported to the printer.
With PR#173 we have this operation separated into a fast and a slow stage (for MK3S with the chimney).
It looks like the printer could benefit from knowing if the MMU is still pushing fast
or when it entered the slow stage (to prevent ramming hard the Bondtech gears)

Along with this new state being reported, we also introduce a new ErrorCode::FSENSOR_TOO_EARLY
which basically means that the fsensor triggered in the fast feeding stage.
2022-05-23 07:41:54 +02:00
D.R.racer c5aea89cac Report FINDA/EEPROM disrepancy to the printer 2022-05-13 08:17:28 +02:00
D.R.racer 6b53db7610 Rebase onto main 2022-02-17 08:21:15 +01:00
D.R.racer b36e6b99a1 Add Pulley as a Movable module
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
2022-02-17 08:21:15 +01:00
D.R.racer 21390cefe1 Add Homing/Stalled error codes for Pulley, Idler, Selector 2022-01-18 09:43:18 +01:00
D.R.racer 206923598b Fix error codes formatting 2021-10-12 18:11:05 +02:00
3d-gussner dbf26d13ac Make search for error codes easier 2021-10-12 18:11:05 +02:00
D.R.racer 1a5cd52d58 Fix some doxygen comments 2021-09-29 13:28:34 +02:00
D.R.racer 8a5614844c Add more error codes for the printer's perspective 2021-09-29 13:28:34 +02:00
Yuri D'Elia ee8c80e5c4 Motion: Panic if queue is full
If the queue is full and a new move is queued, panic!

Introduce a new error code QUEUE_FULL to help diagnose situations where
the queue is handled improperly: likely one of the state machines not
waiting for the previous actions to finish.

PulseGen::PlanMove returns a boolean if the queue cannot be moved.
We could extend this to Motion::PlanMove, however all moves would then
have to check for this. Having a global check such as this ensures
we never ignore such situation.
2021-09-02 12:00:59 +02:00
D.R.racer 5571e77809 Improve/fix some comments 2021-09-02 08:35:56 +02:00
D.R.racer 9ba116e06e Handle slot indices out of range correctly at top level
Besides Unload Filament, which only operates on active slot, all other
top level state machines check the validity of the command's parameter.
If the parameter is out of range for available slots, they return
ErrorCode::INVALID_TOOL now.
2021-08-12 10:30:40 +02:00
D.R.racer ef96d998a3 Link top level error reporting to TMC2130 error flags 2021-08-02 07:45:45 +02:00
D.R.racer d94ad8b90e Merge coil errors, fix bit masks 2021-08-02 07:45:45 +02:00
D.R.racer f7c3d0b479 Fix axis bit masks 2021-08-02 07:45:45 +02:00
D.R.racer 751ee46450 Add bit masks for error codes for the TMC drivers
+ add common error handling for idler and selector
+ improve error handling in command_base
+ rename ERR1xxxx errors to ERRxxxx (remove the '1')
2021-08-02 07:45:45 +02:00
D.R.racer f5df642eb5 Improve error codes
- Distinguish among FINDA on/off failuje
- The same applies to newly introduced Filament sensor errors
- Add TMC init error
- Add a communication error ID - to be used on the printer
2021-08-02 07:45:45 +02:00
D.R.racer 3f98ec03ca Fix doxygen documentation for the logic layer 2021-06-30 07:39:31 +02:00
D.R.racer 317a486d1e Logic layer Eject filament unit tests
initial setup, it compiles, but is blocked by Unload filament
2021-06-21 10:26:04 +02:00
D.R.racer dfb57bcae5 Add Load filament state machine
+ printer's fsensor (external) module
+ state machine for loading to bondtech
2021-06-14 07:34:59 +02:00
D.R.racer 5b4eb0cee3 Extract Unload filament into a separate file
+ cleanup the object structure
+ add no_command as the starting "operation" to simplify the rest of the command handling at runtime
2021-06-14 07:34:59 +02:00