Based on long-term test experience - saves some code + prevents the user from entering hard-to-understand states.
Only Retry remains as the one and only way of recovering from errors.
Intended for scenarios when FINDA used to be OFF but accidentally became ON without a reason.
The user is obliged to inspect FINDA and tune its switching.
This is to solve a potential problem while feeding to printer's drive gears - while disengaging the Idler, the Pulley was still rotating to avoid grinding the filament (printer is pulling it).
Other filaments could have moved a bit when the Idler's bearings ran over them while the Pulley was still rotating slowly -> the filament could have been moved into the Selector's path causing trouble (especially when not used in the print).
Therefore, the Idler disengages partially now - moves into an intermediate position between the slots.
Then, the Pulley is completely stopped and after that the Idler does a full disengage like before.
If the MMU receives a command LoadFilament with a slot number SL we reject
the command to avoid moving the selector (effectively cutting the piece of filament present in FINDA).
That includes the scenario when the selector is standing at the very same slot SL, because the filament could be held by the printer (i.e. loaded in the nozzle).
There is one special case though - same slot AND filament load state == InSelector (it MUST NOT be anywhere farther)
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
This solves a number of issues - if FINDA or FSensor failed,
the unload was never "complete" - filament was stuck in the selector
blocking it from normal operation.
Now, after all errors have been resolved, filament is explicitly FED
into FINDA and then RETRACTED to Pulley.
Solves an interesting tiny issue introduced in the previous commits.
When we start with the filament in selector, the corresponding LED
is set to ON. However, all of the logic state machines only operated
on the LED pair of the active slot -> the starting LED may have been
left ON in some edge cases.
Now, this is resolved by clearing all other LEDs except for the active
slot where appropriate.
Both movable components now perform homing sequences transparently
whenever the logic layer invalidates the homingValid flag.
That reflects the fact, that the user may have moved the Idler or Selector
while trying to resolve a HW issue with un/loading filament.
Basic rules:
- Idler gets rehomed immediately and then moves into the target slot position
- Selector rehomes once it is possible - i.e. when filament load state
is AtPulley - then it immediately and spontanneously executes the homing
sequence and then returns to the desired state
Motivation:
- resolve startup issues (EEPROM says we have filament, but FINDA is not triggered)
- resolve accidental moves of Idler and/or Selector while
digging out stuck filament from the unit
we may discuss when to check for the FSensor state and why,
but this approach seemed to me like the least invasive method
of just checking the fsensor state and reporting an error in case
it didn't switch off.
That includes:
- introduce pulley slow feedrate and fsensor-to-nozzle distance
in config necessary for slowly feeding the filament from fsensor into the nozzle.
(the constant is subject to extraction into some other config as it has to be used in the printer as well).
- update FeedToBondtech accordingly to perform a gentle push into the nozzle
after fsensor detects the filament + update its unit tests.
- slight cleanup of LoadFilament + fix its unit tests
- add FeedingToNozzle progress code, as it might be interesting
to inform the printer about this task in the future
- revert non-clean changes from RetractFromFinda - it should not disengage the idler
- revert incorrect + fix ToolChange
- clean-up UnloadFilament
- Distinguish among FINDA on/off failuje
- The same applies to newly introduced Filament sensor errors
- Add TMC init error
- Add a communication error ID - to be used on the printer
Implement Motion::SetEnabled (for symmetry with TMC2130::SetEnabled).
Rename DisableAxis to Disable and use the new SetEnabled. This makes the
member names more consistent.