The reasons for this change are:
- NoCommand is used during the lifetime of the firmware as a fallback in case an unknown command is received (simplifies command handling code). It must remain not doing anything.
- StartUp became a complex infrastructure which needs to "live" until an error is fixed (if any). That requires a "standard" StateInner() function which waits for the user to resolve the error.
Unit tests renamed as well.
It looks we have some kind of leak when filament sensor state is not completely coherent with FINDA state.
This is yet to be discovered and fixed with some unit tests.
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
- circular buffer can return its count of elements (even though a better solution may be implemeted later)
- stub_motion can handle multiple planned moves
- improved load/unload filament tests
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
This solves a number of issues - if FINDA or FSensor failed,
the unload was never "complete" - filament was stuck in the selector
blocking it from normal operation.
Now, after all errors have been resolved, filament is explicitly FED
into FINDA and then RETRACTED to Pulley.
- fix homing procedure for Idler and Selector
(homing now ends with a move to the Parking position)
- fix unit tests' startup conditions with regard to necessary
homing of Idler and Selector
TODO: still test_cut_filament fails for minor reasons
- Remove the combined PlanMove(a,b,c,rate) call. If we allow the units
of the various motors to be changed at compile time, the unit of
rate can vary between axes.
- Build PlanMove on top of the absolute PlanMoveTo.
- Add required stubs for TMC2130.
- Allow each axis mode to be set independently, since we have this
feature for free anyway.
- Rework internals to use PulseGen data types and structs.