If the MMU receives a command LoadFilament with a slot number SL we reject
the command to avoid moving the selector (effectively cutting the piece of filament present in FINDA).
That includes the scenario when the selector is standing at the very same slot SL, because the filament could be held by the printer (i.e. loaded in the nozzle).
There is one special case though - same slot AND filament load state == InSelector (it MUST NOT be anywhere farther)
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Both movable components now perform homing sequences transparently
whenever the logic layer invalidates the homingValid flag.
That reflects the fact, that the user may have moved the Idler or Selector
while trying to resolve a HW issue with un/loading filament.
Basic rules:
- Idler gets rehomed immediately and then moves into the target slot position
- Selector rehomes once it is possible - i.e. when filament load state
is AtPulley - then it immediately and spontanneously executes the homing
sequence and then returns to the desired state
Motivation:
- resolve startup issues (EEPROM says we have filament, but FINDA is not triggered)
- resolve accidental moves of Idler and/or Selector while
digging out stuck filament from the unit
Besides Unload Filament, which only operates on active slot, all other
top level state machines check the validity of the command's parameter.
If the parameter is out of range for available slots, they return
ErrorCode::INVALID_TOOL now.