This PR brings the option to move the selector directly using
buttons of the MMU - obviously while the MMU is idle and no
filament is stuck in the selector.
Left/Right buttons move the selector Left/Right.
Middle button performs a LoadFilament (into the MMU) on the active slot.
With this PR a change of LoadFilament behavior is also introduced.
Now, LoadFilament spins the Pulley for infinite time while waiting
for either FINDA trigger and/or a button pressed.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Solves an interesting tiny issue introduced in the previous commits.
When we start with the filament in selector, the corresponding LED
is set to ON. However, all of the logic state machines only operated
on the LED pair of the active slot -> the starting LED may have been
left ON in some edge cases.
Now, this is resolved by clearing all other LEDs except for the active
slot where appropriate.
Load filament performs feed to FINDA and retract:
- engage idler
- feed normal to FINDA with config::feedToFinda distance until FINDA triggers
- retract normal and as soon FINDA un-triggers move back to PTFE config::cuttingEdgeToFindaMidpoint
- disengage the idler
That implied introducing another substate machine - RetractFromFinda, which does the opposite
of FeedToFinda while also checking for the FINDA switching off while retracting filament.
Still, ToolChange and CutFilament need fixing with this change
- Remove the combined PlanMove(a,b,c,rate) call. If we allow the units
of the various motors to be changed at compile time, the unit of
rate can vary between axes.
- Build PlanMove on top of the absolute PlanMoveTo.
- Add required stubs for TMC2130.
- Allow each axis mode to be set independently, since we have this
feature for free anyway.
- Rework internals to use PulseGen data types and structs.