This is to solve a potential problem while feeding to printer's drive gears - while disengaging the Idler, the Pulley was still rotating to avoid grinding the filament (printer is pulling it).
Other filaments could have moved a bit when the Idler's bearings ran over them while the Pulley was still rotating slowly -> the filament could have been moved into the Selector's path causing trouble (especially when not used in the print).
Therefore, the Idler disengages partially now - moves into an intermediate position between the slots.
Then, the Pulley is completely stopped and after that the Idler does a full disengage like before.
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Solves an interesting tiny issue introduced in the previous commits.
When we start with the filament in selector, the corresponding LED
is set to ON. However, all of the logic state machines only operated
on the LED pair of the active slot -> the starting LED may have been
left ON in some edge cases.
Now, this is resolved by clearing all other LEDs except for the active
slot where appropriate.
Both movable components now perform homing sequences transparently
whenever the logic layer invalidates the homingValid flag.
That reflects the fact, that the user may have moved the Idler or Selector
while trying to resolve a HW issue with un/loading filament.
Basic rules:
- Idler gets rehomed immediately and then moves into the target slot position
- Selector rehomes once it is possible - i.e. when filament load state
is AtPulley - then it immediately and spontanneously executes the homing
sequence and then returns to the desired state
Motivation:
- resolve startup issues (EEPROM says we have filament, but FINDA is not triggered)
- resolve accidental moves of Idler and/or Selector while
digging out stuck filament from the unit
Besides Unload Filament, which only operates on active slot, all other
top level state machines check the validity of the command's parameter.
If the parameter is out of range for available slots, they return
ErrorCode::INVALID_TOOL now.