Fix a minor issue where once the FILAMENT_EJECTED error screen
is shown on the MK3S+, the LEDs will stay blinking red even after
the user has removed the filament and clicked "Done".
My proposal is to turn the LED off.
Steps to reproduce:
1. Boot up printer and MMU in a clean state
2. MK3S+: on the LCD click "Load to Nozzle"
3. Once the loading is done, click "Unload filament"
4. Once unloading is done, click "Eject filament"
5. FILAMENT_EJECTED MMU error screen appears on the printer's UI
6. Remove the filament and select "Done".
* Expected behavior: Blinking red LED turns off (or goes green).
* Actual behavior: LED continous to blink red with no error screen.
Change in memory:
Flash: +16 bytes
SRAM: 0 bytes
This is to solve a potential problem while feeding to printer's drive gears - while disengaging the Idler, the Pulley was still rotating to avoid grinding the filament (printer is pulling it).
Other filaments could have moved a bit when the Idler's bearings ran over them while the Pulley was still rotating slowly -> the filament could have been moved into the Selector's path causing trouble (especially when not used in the print).
Therefore, the Idler disengages partially now - moves into an intermediate position between the slots.
Then, the Pulley is completely stopped and after that the Idler does a full disengage like before.
If the MMU receives a command LoadFilament with a slot number SL we reject
the command to avoid moving the selector (effectively cutting the piece of filament present in FINDA).
That includes the scenario when the selector is standing at the very same slot SL, because the filament could be held by the printer (i.e. loaded in the nozzle).
There is one special case though - same slot AND filament load state == InSelector (it MUST NOT be anywhere farther)
This commit looks horribly complex, but the main idea is to have each of the logic::commands
report their terminal OK state in the same way. That allow for leveraging this very moment
to initiate the idle timeout.
Additionally, I wanted to hide the logic of idle mode detection, which resulted in moving the
top level logic from main.cpp into logic/idle_mode.cpp and a set of additional files to compile
in unit tests.
This PR brings the following improvements:
- unifies the error handling of TMC and Homing/Stallguard errors on all motorized modules (Idler, Selector, Pulley)
- now we distinguish between Homing and TMC errors + we have a separate handling of these two kinds into CommandBase unified for all motorized modules
- adds unit tests to verify the function
- fixes SetFINDAStateAndDebounce (didn't obey the press parameter before)
Besides Unload Filament, which only operates on active slot, all other
top level state machines check the validity of the command's parameter.
If the parameter is out of range for available slots, they return
ErrorCode::INVALID_TOOL now.
Implement Motion::SetEnabled (for symmetry with TMC2130::SetEnabled).
Rename DisableAxis to Disable and use the new SetEnabled. This makes the
member names more consistent.
- Remove the combined PlanMove(a,b,c,rate) call. If we allow the units
of the various motors to be changed at compile time, the unit of
rate can vary between axes.
- Build PlanMove on top of the absolute PlanMoveTo.
- Add required stubs for TMC2130.
- Allow each axis mode to be set independently, since we have this
feature for free anyway.